30
AGUADENS
COSMOGAS
5.14.5 - “Split 80/80PP” System (Type C43;
C53; C83): installation examples
In figure 5-22 two examples of installation are given:
- exhaust into chimney with collection of condensate inside
the appliance itself.
The horizontal part of the fumes exhaust must slope towards
the appliance.
The intake must slope towards the outside to prevent rain
water entering.
- exhaust to the outside directly with the appliance pipes with
condensate collection inside the appliance itself.
The intake must slope towards the outside to prevent rain
water entering.
Figure 5-22 - Example of “80/80 PP System”
installation
Figure 5-23 - Example of “80/80 PP System” installation
5 - INSTALLATION
In figure 5-23 it is possible to see a separated type of fumes
exhaust, where fumes exhaust was realised with flexible hose
in polypropylene for piping of technical cells.
The condensate produced in the vertical pipe must all be
conveyed into the appliance.
The intake must slope towards the outside to prevent rain
water entering.