16
AGUADENS
COSMOGAS
5.1 - Opening the packaging
The appliance is supplied in cardboard packaging. Open
following the instructions given on the flaps of the packaging
itself.
5.2 - Dimensions and minimum
safety clearances
It is necessary to leave free spaces around the appliance as
illustrated in figure 5-1 both for installation and maintenance.
5.3 - Choosing suitable
installation location
ATTENTION !!! The appliance must be installed
exclusively on a solid, vertical wall, which can support
the weight.
The appliance must be installed in a suitable room taking
into account the following factors:
- connection of the exhaust/air intake pipes;
- connection of the gas supply pipe;
- connection to the cold water supply;
- connection of the domestic hot water supply;
- electrical connection;
- connection of the siphon and safety valve to a suitable
drain;
5.4 - Mounting the appliance
Refer to figure 5-4:
1.- place the paper template, provided with the appliance,
against the wall;
2.- check that the template is square;
3.- mark the holes for the plugs and hydraulic fittings on the
wall;
4.- remove the paper template;
5.- make the holes “A” and introduce the wall plugs “B”;
6.- hang the appliance on the plugs “C”
7.- make the appliance hydraulic and gas connections;
8.- make the hydraulic fittings.
5.5 - Domestic hot and cold water
CAUTION !!! water quality must be within
6,5<pH<8,5 acidity value.
CAUTION !!! If water hardness exceeds 20°f (200
mg/l or 11,2°dH) a water softner must be installed on
the incoming cold water supply.
CAUTION !!! If water heater works at
temperature higher than 60°C and until 75°C, water
hardness must be lower than 15°f (150 mg/l or 8,4°dH)
CAUTION !!! Water hardness must not be
reduced lower than 5°f (50mg/l or 2,8°dH). Softened
water than 5°f (50mg/l or 2,8°dH) is aggressive and can
corrode the heat exchanger reducing life expectation.
CAUTION !!!
Install a filter with mesh no wider
than 0.5 mm² in the domestic cold water inlet.
1 - 3/4” recirculation
2 - 1” D.H.W. outlet
3 - 3/4” gas inlet
4 - 3/4” cold water inlet
5 - Fumes exhaust/Air intake
6 - Support attachments
7 - Ø20 condensate drain
5 - INSTALLATION
Figure 5-1 - Minimum safety distances
Figure 5-2 - Dimensions and attachments centre to
centre distances AGUADENS 16 and 22