9-3
MINOR TROUBLES & SOLUTIONS
TROUBLE
PROBABLE CAUSE
SUGGESTED REMEDY
Saw blade motor does not run
even though blade drive button
is pressed.
Overload relay activated
Reset
Saw blade is not at forward
limit position.
Press SAW FRAME
FORWARD button
MOTOR TROUBLES & SOLUTIONS
TROUBLE
PROBABLE CAUSE
SUGGESTED REMEDY
Motor will not start
Magnetic switch open, or
protector open.
Reset protector by pushing red button (inside
electric box.)
Low voltage
Check power line for proper voltage.
Open circuit in motor or loose
connections.
Inspect all lead terminations on motor for loose
or open connections.
Motor will not start,
fuse or circuit
breakers “blow”.
Short circuit in line, cord or
plug.
Inspect line, cord and plug for damaged
insulation and shorted wire.
Short circuit in motor or loose
connections
Inspect all lead terminations on motor for loose
or shorted terminals or worn insulation on
wires.
Incorrect fuses or circuit
breakers in power line.
Install correct fuses or circuit breakers.
Motor fail to develop
full power. (Power
output of motor
decreases rapidly
with decrease in
voltage at motor
terminals.)
Power line overloaded with
lights, appliances and other
motors.
Reduce the load on the power line.
Undersize wires or circuit too
long.
Increase wire sizes, or reduce length of wiring
General overloading of power
company‘s facilities.
Request a voltage check from the power
company
Motor overheat
Motor overloaded.
Reduce load on motor
Air circulation through the
motor restricted.
Clean out motor to provide normal air
circulation through motor.
Motor stalls
(Resulting in blown
fuses or tripped
circuit breakers)
Short circuit in motor or loose
connections.
Inspect terminals in motor for loose or shorted
terminals or worn insulation on lead wires.
Low voltage
Correct the low line voltage conditions.
Incorrect fuses or circuit
breakers in power line.
Install correct fuses circuit breakers.
Motor overloaded
Reduce motor load.
Frequent opening of
fuses or circuit
breakers.
Motor overloaded
Reduce motor load
Incorrect fuses or circuit
breakers.
Install correct fuses or circuit breakers.
Summary of Contents for SH-460M
Page 2: ......
Page 4: ......
Page 10: ......
Page 19: ...1 9 Illustration Safety Labels ...
Page 24: ...2 4 FLOOR PLAN Machine top view Machine side view ...
Page 25: ...2 5 Machine front view ...
Page 26: ......
Page 36: ......
Page 52: ...5 2 ...
Page 53: ...5 3 ...
Page 54: ...5 4 ...
Page 55: ...5 5 ...
Page 56: ...5 6 1040325 張 鴻 昌 ...
Page 57: ...5 7 1040325 張 鴻 昌 ...
Page 58: ...5 8 1040325 張 鴻 昌 ...
Page 59: ...6 1 Section 6 HYDRAULIC SYSTEM HYDRAULIC DIAGRAMS ...
Page 60: ...6 2 ...
Page 82: ...10 2 ...
Page 83: ...10 3 ...
Page 84: ...10 4 ...
Page 85: ...10 5 ...
Page 86: ...10 6 ...
Page 87: ...10 7 ...
Page 88: ...10 8 ...
Page 89: ...10 9 ...
Page 90: ...10 10 ...
Page 91: ...10 11 ...
Page 92: ......
Page 94: ......
Page 95: ......