VOUT_COMMAND
[21h]
R/W Word (only CHS400/500-I)
The output voltage can be programmed within the setting range
Display format
: Linear(Vo)
Initial setting
: 12 [ V ]
Range of setting and reading
: 10.8 - 13.2 [ V ]
*1
*1: The value which added VOUT_TRIM [ 22h ] becomes the upper limit.
Also, the value which exceeds VOUT_MAX [ 24h ] can not be set.
VOUT_TRIM
[22h]
R/W Word (only CHS400/500-I)
Sets output voltage trim value. The two bytes are formatted as a two’s complement binary mantissa,
sets in conjunction with the exponent set in VOUT_MODE.
Display format
: Linear(Vo)
Initial setting
: 0 [ V ]
Range of setting and reading
: ±5.1 [ V ]
*1
*1: When either VOUT_COMMAND [ 21h ]
,
VOUT_MARGIN_HIGH [ 25h ]
,
VOUT_MARGIN_LOW [ 26h ] adds
on VOUT_TRIM [ 22h ] becomes out of the range, it is not possible to be set.
VOUT_MAX
[24h]
R/W Word (only CHS400/500-I)
Sets the maximum possible value setting of the output voltage.
It isn't possible to change the maximum setting value.
Display format
: Linear(Vo)
Initial setting
: 15.0 [ V ]
Range of setting and reading
: 8.1 - 15.0 [ V ]
Applications manual
For CHS300/400/500-
I
series