© Corroventa Ltd.
2017.05
22 (43)
Setup and Maintenance Menus
Under Setup and Maintenance, functions that are not
required for normal operation are found.
Date and Time
: Setting of system date and time.
Format is YY:MM:DD / HH:MM.
Language:
Selection of language for the interface.
Menu System:
The menu system is by default set to
Advanced with all functions visible and accessible. If set
to Basic, the more advanced functions are removed
from the menu system.
Key Pad lock
: Possibility to activate/deactivate the key
pad lock.
RH Hysteresis:
Possibility to adjust the hysteresis
settings for RH Control Mode. The position of the
setpoint in the operation span can be set as well as the
hysteresis value.
Dew point Hysteresis:
Possibility to adjust the
hysteresis settings for Dew point (DEW) Control Mode.
The position of the setpoint in the operation span can
be set as well as the hysteresis value.
Mixing ratio Hysteresis:
Possibility to adjust the
hysteresis settings for Mixing ratio (MIX) Control Mode.
The position of the setpoint in the operation span can
be set as well as the hysteresis value.
Run built-in test:
A built-in self test that is available for
service technicians.
Reset Service Time:
The machine is set to give a service
reminder once every 12 months. When service has
been performed, this service reminder can be reset
using this function.
View sensor data:
Functionality intended for service
technicians.
Summary of Contents for A2 ES
Page 1: ...A2 ES A4 ES A4 ESX ADSORPTION DEHUMIDIFIERS USER MANUAL...
Page 39: ...Interface Map for CTR A2ES CTR A4 ES and CTR A ES Top Menu...
Page 40: ...Sublevels Info Statistics Info Reset Info Info Info Info Info...
Page 42: ...Create Activate Edit Edit Change...
Page 43: ...Info Change OK Info Info...
Page 44: ...Info Change OK...