© Corroventa Ltd.
2017.05
33 (43)
•
Reattach the wet air hose. On the
A2ES, put the gable back in place
while sliding the hose onto the spigot
of the heater cover on the rotor
assembly.
•
Put the lid back on the dehumidifier,
re-connect the three cable
assemblies. Mount and tighten the
four screws.
6.
Inspect and verify the good function of the
dehumidifier as follows:
Connect power to the dehumidifier and put it
in manual mode. Verify that it starts, that the
fan starts running.
Verify, by looking into the wet air outlet that
the rotor is rotating. Put one hand in front of
the wet air outlet and verify that the air feels
warm, thus that the heater is functioning.
Accessories and consumables
The following articles are available as accessories and consumables to the CTR A ES machines:
Article number
Name
01100
Humidistat, HR1-5 (Adapter cable, hygrostat req)
20184
Process air filter
1002749
System cable, 0.5m
1002748
System cable, 5m
1002816
Adapter cable, hygrostat.
1002817
External RHT sensor ES series