SRP 003-485 • Issue 6 • October 2006
Page 27
SCF-6 Canister and Inline Splice Closures
Step 2
Pop the clamping bar locks out of the inserts.
Step 3
Place the clamping bars on the closure cover as shown in Figure 45.
Step 5
Tap lightly in a downward
direction to set the clamping
bar locks (Figure 47).
Refer to SRP 206-287 (Mechanical End Cap Inline Closure Sealing Checklist) to ensure all
critical
steps in Section 5.13 for sealing the closure have been performed accurately.
Figure 45 — Install Clamping Bars
KPA-0488
Figure 46 — Hammer Clamping Bars
Figure 47 — Hammer Locks
KPA-0489
Step 4
Close the clamping bars by tapping alternately with a hammer.
IMPORTANT:
DO NOT hammer directly on the clamping bars; this will damage them. Place a
block of wood over the clamping bars and tap lightly with a hammer (Figure 46).
When the clamping bars are completely closed, a 0.28-inch gap will remain between
the bars and the clamping bar locks will align with the holes in the cover.
KPA-0487
Bar Locks
Clamping Bars
KPA-0493