SCF-6 Canister and Inline Splice Closures
Page 24
SRP 003-485 • Issue 6 • October 2006
Proceed to Section 5.13 to seal an inline closure.
Proceed to Section 5.14 to seal a canister closure.
5.13
Seal the Inline Closure
NOTE:
Do not use encapsulant in SCF closures.
4.13.1
Install sealing gasket
Step 1
Verify there is no sealing tape in the sealing ring channel. Flatten any sealing tape
with the blade of a screwdriver.
Step 2
Use the supplied brush to apply UCN lubricant to the sealing ring channel on the
end cap (Figure 36).
Step 3
Apply a thin coat of UCN lubricant to the mating surfaces of the end cap gasket.
Insert the bottom part of the sealing gasket clip into the hole in the sealing ring
(Figure 37).
Step 3
Store the end cap gauge
between the splice tray
stacker and the frame
(Figure 34).
Step 4
Secure all buffer tubes,
splice trays and the
combination wrench
using the hook-and-loop
straps.
IMPORTANT:
Position the wrench
so that it does not
interfere with the
dome cover during
installation.
Step 5
Reposition the adjuster
bracket to keep the trays
from moving, if
necessary
(Figure 35).
Figure 35 — Adjuster Bracket
Figure 34 — Store End Cap Gauge
KPA-0478
End
Cap
Gauge
Straps
Adjuster
Bracket
KPA-0538
LU
B
B
R
I
ICA
N
N
T
T
KPA-0479
Figure 36 — Lubricate Channel
Figure 37 — SCF Gasket Clip
KPA-0649
Top
Bottom