SRP 003-485 • Issue 6 • October 2006
Page 17
SCF-6 Canister and Inline Splice Closures
Figure 16 — Dummy Plug
Step 5
Repeat Section 5.4.1 and 5.4.2 for the other cable to be installed in the express
port, if applicable.
5.4.3
Use a dummy plug
When the closure only has one cable installed in either
end cap, use a dummy plug (p/n SCF-4-6-PLUG,
purchased separately) to fill the unused port.
Step 1
If using a dummy plug follow instructions
in Section 5.4.2 to install sealing paste and
tape to dummy plug.
Step 2
Install dummy plug with the closed end of
the plug flush against the outside of the
end cap (Figure 16).
5.4.4
Install cable
Step 1
Wrap hose clamps and restraint caps with vinyl tape to prevent the sharp edges
from damaging the fiber.
Step 2
Place one side of the express cable sheath in the express port on the untaped end
cap half by inserting the strain-relief bracket in the tracks.
Step 3
Place the other side of the express cable sheath on the taped end cap half
(Figure 17) in the center express port by inserting the strain-relief bracket in the
tracks.
Figure 17 — Install Cable into End Cap
Strain-relief Tracks
Sealing
Ring
Channel
Sealing
Ring
Channel
Vinyl Tape
Dummy Plug
KPA-0447
KPA-0503