p/n 003-304
Corning Cable Systems
Standard Recommended Procedure (SRP) 003-304
Issue 9, July 2004
Page 1 of 12
Environmental Distribution Center (EDC-02P-NH)
Contents
1. General ........................................................ 1
2. Description .................................................. 1
3. Precautions .................................................. 2
4. Tools and Materials ..................................... 3
5. Components................................................. 3
6. Unpacking Stubbed Units ........................... 3
7. Installing Holes ............................................ 4
8. Mounting ..................................................... 4
9. Preparing the Cable ..................................... 5
10. Connector Panels ........................................ 7
11. Splicing ........................................................ 8
12. Installing Fan-outs ....................................... 9
13. Installing Drop Cables ..............................10
14. Maintenance ..............................................11
15. Specifications ............................................. 11
1.
General
1.1
This instruction describes the
recommended procedure for the installation of
the two-panel Environmental Distribution
Center (EDC) (p/n EDC-02P-NH)
manufactured by Corning Cable Systems.
1.2
To purchase any accessories that are sold
separately, contact your Corning Cable Systems
service representative for assistance.
1.3
This document is being reissued to clarify
cable cleaning directions.
NOTE:
Read and understand this procedure (as
well as the instructions provided with related
assemblies) before beginning an installation. Make
sure you know how the unit will be mounted and
how the distribution cable and drop cable will be
routed to the unit.
2.
Description
2.1
The EDC is a cabinet designed for storage
and protection of fiber optic connections and
splices in an outdoor environment. The cabinet
carries a NEMA 250 Type 4X and Type 13
rating in addition to a IEC 529 IP66 rating.
The unit provides environmental protection
and strain-relief for one distribution cable and
up to six drop cables.
2.2
Connector panels are used to provide
interconnection between the distribution and
drop cables. The EDC accommodates up to two
LANscape
®
connector panels. Some connector
panels come with icons. Colored icons are
available with different symbols to be used as a
quick visual reference of the data type at each
connector location. Panels and connector panel
icons are ordered separately.