ONE SD-LAN Wall
Mount Splitter Housing
(1LAN-SPLT-132-486C)
STANDARD RECOMMENDED PROCEDURE 000-000-AEN | ISSUE 1 | MARCH 2018 I
Page 3
4.1 Wall Mounting PSU6 (Remote Power Option)
Step 1
Remove the rack-mounting brackets and set the
screws aside.
Figure 3 Dual Gang Box Mounting
Step 2
Using the four screws (previously set aside),
assemble the wall-mount brackets onto the sides
of the PSU6 so that the unit can be mounted
belly-to-wall. See Figure 3.
Notes: The unit should be mounted on the wall
with the DC connectors facing sidewards. See
Figure 5. Make sure that there is enough space
at the rear to insert/extract the PSMs.
Step 3
Using the wall-mount bracket keyholes as a
guide, mark the holes to be drilled on the wall.
Mount the PSU 7 inches horizontally from the
Wall Mount Splitter Housing. See Figure 4
Notes: This distance will affect the strip lengths
of the composite drop cables. If mounting is more
than 7 inches from splitter housing strip lengths
wil Need to be adjusted to allow for necessary
copper conductor length to reach PSU6 power
ports
Step 4
Insert appropriate bolts and mount unit.
Figure 4 Housing and PSU6 Wall Mounting