ONE SD-LAN Wall
Mount Splitter Housing
(1LAN-SPLT-132-486C)
STANDARD RECOMMENDED PROCEDURE 000-000-AEN | ISSUE 1 | MARCH 2018 I
Page 7
Step 1
Remove one of the hole plugs from the bottom of the housing. Install an appropriate size fitting and
conduit (if conduit is used) per standard local practices and ensure proper sealing. Feed the end-
point cables into the bottom chamber through the fitting.
Step 2
Strip 95 inches of the end-point cable jacket from the cables with proper cable entry tools and
procedures exposing the fiber and copper conductors.
Step 3
Route one loop of fiber/copper around the radius guides in counter clockwise direction.
Step 4
Place spiral wrap around the bundle of fibers where they will transition from the bottom chamber to
the customer/drop adapter field. Secure spiral wrap to inner security door to prevent fiber from being
pinched when closing the door
Step 5
Route the fibers to the front of the housing, trimming lengths as needed and terminate fibers.
Step 6
Align the key on the connector with the key on the connector adapter. Install the connector into the
adapter. Park unused terminated fibers in the parking area.
Step 7
Route copper through one of the drop port holes out of the housing.
Step 8
Place spiral wrap around copper conductor bundles and secure.
Step 9
Route copper conductor bundle to PSU6 and terminate into power port connectors.
Note: See PSU6 Quick Start Guide
Figure 8