11 Testing | 

11.1  Provisioning Tests | 

Equipment should be tested from the source (or central office) to receiver at the time of provisioning to verify signal 
continuity and acceptable loss limits. Use an optical power meter to verify signal continuity and determine whether 
loss measurements are within specified local standards. 

11.2  Troubleshooting Tests | 

An optical power meter can be used to perform the first step in troubleshooting. A power meter designed for 
measuring only dBm power levels is suitable for maintenance purposes. 

For high attenuation: 

  Remove connector and reclean connector and adapter. 

  Verify cable ties are not too tight. 

  Maintain appropriate fiber bend radius. Make sure there are no sharp bends. 

Once a fault is isolated to the installed cable link, an optical time domain reflectometer (OTDR) is needed. An 
OTDR can locate fiber events and measure the losses attributable to cable, connectors, splices, and/or other 
components. The graphical display of loss over a cable’s entire length provides the most revealing analysis and 
documentation available on a cable link, commonly referred to as its signature trace. Corning recommends 
performing an OTDR analysis to document the integrity of the cable system, locate and measure each event or 
component, and uncover faults throughout the cable. Follow the instructions provided with the OTDR tester you are 
using. 

12 Maintenance and Repair Procedures | 

12.1  Maintain the Housing 

No routine maintenance of this product is required to keep it in operational order. In the event of loss of service or 
low performance, test the connections as described in Section 10. Reenter the bottom chamber, if necessary, to 
determine which components are defective. 

12.2  Reenter the Housing 

Use a 3/8-in can wrench to loosen the external security screw and then depress the access latches to open the 
front cover. 

12.3  Replace Components 

Contact Corning Engineering Services at 1-800-743-2671 for instructions to repair or replace broken or defective 
components. 

Summary of Contents for 1LAN-SPLT-132-486C

Page 1: ...ONE SD LAN Wall Mount Splitter Housing 1LAN SPLT 132 486C STANDARD RECOMMENDED PROCEDURE 000 000 AEN ISSUE 1 MARCH 2018 I Page 1 CMA 477 AEN 1 General Figure 1...

Page 2: ...lan Choose a vertical surface near approved ground but away from downspouts permanent water sprinklers or other water sources Ensure the housing is easily accessible from the front to allow technician...

Page 3: ...mounted on the wall with the DC connectors facing sidewards See Figure 5 Make sure that there is enough space at the rear to insert extract the PSMs Step 3 Using the wall mount bracket keyholes as a g...

Page 4: ...4 5 Accessing the Housing Step 1 Use a 3 8 in can wrench to loosen the security screw on the front cover Figure 5 ONT Fiber Port Step 2 Depress the access latches on the side of the unit and open the...

Page 5: ...ocal practices and ensure proper sealing Feed the end point cables into the housing through the fitting Figure 6 Step 2 Strip 65 inches of the feeder cable jacket with proper cable entry tools Step 3...

Page 6: ...mmend the use of safety glasses spectacles conforming to ANSI Z87 for eye protection from accidental injury when handling chemicals cables or working with fiber Pieces of glass fiber are very sharp an...

Page 7: ...in counter clockwise direction Step 4 Place spiral wrap around the bundle of fibers where they will transition from the bottom chamber to the customer drop adapter field Secure spiral wrap to inner s...

Page 8: ...AN SPLT 132 486C STANDARD RECOMMENDED PROCEDURE 000 000 AEN ISSUE 1 MARCH 2018 I Page 8 Figure 9 8 Connecting End point Connectors during Initial Installation Step 1 Select the appropriate connector f...

Page 9: ...Section 6 to connect end points 10 Connector Care and Cleaning WARNING Isopropyl alcohol is flammable with a flashpoint at 54 F It can cause irritation to eyes on contact In case of contact flush eye...

Page 10: ...cate fiber events and measure the losses attributable to cable connectors splices and or other components The graphical display of loss over a cable s entire length provides the most revealing analysi...

Reviews: