9
620917311
CLEANING AND SANITIZING INSTRUCTIONS
WARNING: Disconnect Power Before Cleaning! Do not use metal scrapers, sharp objects or
abrasives on the ice storage hopper, top cover and the agitator disk, as damage may result.
Do not use solvents or other cleaning agents, as they may attack the plastic material.
Soap solution - Use a mixture of mild detergent and warm (100 F) potable water.
Sanitizing solution - Use 1/2 ounce of household bleach in 1 gallon of potable water. Preparing the sanitizing
solution to this ratio will create a solution of 200 PPM.
DISPENSER
1.
CLEANING EXTERIOR SURFACES
Important:
Perform the following daily.
A.
Remove the cup rest from drip tray.
B.
Wash the drip tray with soap solution. Rinse with potable water and allow solution to run down the
drain.
C.
Wash cup rest with soap solution and rinse in potable water. Install the cup rest into the drip tray.
D.
Clean all exterior surfaces with soap solution and rinse with potable water.
2. CLEANING INTERIOR SURFACES
CAUTION: When pouring liquid into the hopper, do not exceed the rate of 1/2 gallon per
minute.
Important:
Perform the following at least once a month.
A.
Open right hand hopper cover, then remove all ice from hopper.
B.
Lift up and remove the left hand hopper cover.
C.
Remove agitator disk and agitator assembly.
D.
Remove tower cover by removing three thumb screws.
E.
Move the retaining bail to the rear of the tower which will allow removal of the ice chute assembly.
F.
Grasp the ice auger by the shaft end and lift out the auger tube. Take care not to damage either end of
the auger.
G.
Remove the auger tube by lifting upward. The tube will separate into two halves for easy cleaning when
fully removed.
H.
Open the front door of the cabinet below the hopper, this will give you access to the lower auger drive
area and the passage between the hopper and the auger for cleaning.
I.
Using the previously prepared detergent solution clean the hopper covers, agitator disk, and agitator
assembly, interior of the hopper, both halves of the ice chute, auger, auger tubes, and the lower auger
area of the auger housing. Thoroughly rinse all of the previously cleaned with potable water.
J.
Reassemble the agitator assembly and disc into the hopper. Make certain that the retaining screw is
tight.
K.
Using a mechanical spray bottle filled with sanitizing solution, spray the entire interior of the hopper and
the agitator assembly. Go to the lower auger drive area and also spray with sanitizing solution.
Allow to air dry.