Viper Installation, Service & Decommissioning Manual
Publication Number: 620073146SER
- 94 -
© 2022, Marmon Foodservice Technologies Inc.
C
ONDENSER
F
AN
M
OTOR
R
EPLACEMENT
The fan motor is located on the top of the unit, as shown in Figure 76. If the motor needs replacement, perform the proce-
dure in Table 79 to remove and reinstall a motor.
Figure 76. Condenser Fan Mounting Nuts
In Step 1
, disconnect electrical power from the unit. Failure to disconnect the power could result in serious injury, death, or
equipment damage.
C
OMPRESSOR
R
EPLACEMENT
Caution should be used when working with refrigerants. To replace a compressor, perform the procedure in Table 80.
Be sure to reclaim refrigerant when replacing compressor.
I
n Step 1, disconnect electrical power from the unit. Failure to disconnect the power could result in serious injury, death, or
equipment damage.
Table 79.
Step
Action
1
Disconnect electrical power from the unit.
2
Disconnect the fan by unplugging the connector.
3
Remove the four locking nuts securing the fan to the top of the condenser.
4
Lift the fan and shroud off the unit.
5
Remove the four screws and washers securing the fan to the shroud.
6
Replace the fan.
7
Reverse the procedure to install the new fan.
8
Reconnect power to the unit.
Table 80.
Step
Action
1
Disconnect power to the unit.
2
Remove the rear cover and side panels.
3
Label and disconnect all wires from the compressor.
4
Remove the four (4) mounting nuts from the base of the compressor.
5
Remove all insulation from around fittings.
6
Unsweat the suction line from the compressor.