TROUBLESHOOTING
!
WARNING:
Only trained and certified electrical, plumbing and refrigeration technicians should service this unit.
ALL WIRING AND PLUMBING MUST CONFORM TO NATIONAL AND LOCAL CODES. FAILURE TO COMPLY
COULD RESULT IN SERIOUS INJURY, DEATH OR EQUIPMENT DAMAGE.
!
WARNING:
If repairs are to be made to a product system, remove quick disconnects from the applicable product tank, then relieve
the system pressure before proceeding. If repairs are to be made to the CO
2
system, stop dispensing, shut off the
CO
2
supply, then relieve the system pressure before proceeding. If repairs are to be made to the refrigeration system,
make sure electrical power is disconnected from the unit.
Should your unit fail to operate properly, check that there is power to the unit and that the hopper contains ice. If the
unit does not dispense, check the following chart under the appropriate symptoms to aid in locating the defect.
U
NIT
T
ROUBLESHOOTING
Table 17
Symptom
Cause
Remedy
Blown fuse or circuit breaker
A. Short circuit in electrical wiring
B. Inoperable agitator motor (shorted motor)
A. Repair wiring
B. Replace gear motor
Agitator does not turn
A. No power
B. Improperly installed upper ice chute
assembly (Reed switch is not being acti-
vated)
C. Inoperable reed switch
D. Electrical board driver circuit is defective
E. Gear motor has open circuit
F. Reed switch is not activated, improper
assembly of upper ice chute to lower chute
G. Broken wire in the 2-wire harness leading
to the reed switch
H. Bad connection at main control board.
A. Restore power or plug in unit
B. Check the upper ice chute assembly for
proper assembly and operation
C. Replace reed switch
D. Replace main control board
E. Replace gear motor
F. Check to make sure tongue of upper chute
engages into the back of the lower chute,
ensure upper chute engages outside the
lower chute, and snap front of chute into
place
G. Repair of replace 2-wire harness
H. Repair connection or replace 2-wire har-
ness
Ice dispenses continuously
A. Ice gate mechanism is stuck in open posi-
tion
B. Stuck or bent ice lever (does not allow gate
to close and open reed switch)
A. Inspect gasket for proper position. Examine
gate plate to see if it slides freely behind
the lower ice chute.
B. Examine ice dispense lever to see if it is
bent.
Slushy ice or water in hopper
A. Blocked drains in cold plate
B. Poor ice quality due to water quality or ice
maker problems
A. Remove access covers in cold plate cover
& inspect/clean drains
B. Correct water quality or repair ice maker
Beverage does not dispense
A. No 24VAC to valves
B. No CO
2
pressure
A. Restore 24 VAC to valves
B. Restore CO
2
pressure
Beverage is too sweet
A. Valve BRIX requires adjustment
B. Carbonator is not operating
C. No CO
2
in carbonator
D. City water pressure supply low or inconsis-
tent
A. Adjust valve BRIX
B. Repair carbonator
C. Restore CO
2
pressure in carbonator
D. Booster pump must be used if dynamic
water pressure drops below 40 psig.