Summary of Contents for ENDURO-150 6 VALVE

Page 1: ...BEVERAGE DISPENSER MODELS ENDURO 150 6 VALVE Release Date February 25 2004 Publication Number 92096OPR Revision Date March 27 2014 Revision D Visit the Cornelius web site at www cornelius com for all...

Page 2: ...occurrences including but not limited to 1 other than normal and proper use and normal service conditions with respect to the Product 2 improper voltage 3 inadequate wiring 4 abuse 5 accident 6 alter...

Page 3: ...4 Daily Maintenance 4 Weekly Cleaning In Addition To Daily Procedures 4 Cleaning Interior Surfaces Monthly Cleaning 5 Cold Plate Yearly Maintenance 5 Dispensing Valves Daily Cleaning 6 Product Tubing...

Page 4: ......

Page 5: ...ols properly D Do o n no ot tletanyoneoperate theunitwithoutpropertraining This applianceisn no ot tintendedforuse by very young children or infirmpersonswithoutsupervision Y oungchildrenshould besupe...

Page 6: ...g in damage to internal components CO2 CARBON DIOXIDE WARNING DANGER CO2 displaces oxygen Strict attention M MU US ST T be observed in the prevention of CO2 gas leaks in the entire CO2 and soft drink...

Page 7: ...large chunks of ice which jam up inside the hopper will cause failure if the agitator motor and damage to the hopper If bagged ice is used it must be carefully and completely broken into small cube s...

Page 8: ...clean water and allow to air dry 2 Wipe down the exterior of the unit with warm soapy water rinse with clean water and allow to air dry 3 Remove valve nozzles and diffusers and wash in warm soapy wate...

Page 9: ...o air dry 5 Remove merchandiser and ice chute cover from unit 6 With a nylon bristle brush or sponge clean the inside of the ice chute gasket and cover with soap solution and rinse thoroughly to remov...

Page 10: ...different product tube each time until all tubes are filled with the sanitiz ing solution 11 Remove the nozzle and syrup diffuser and clean them in a mild soap solution Rinse with clean water and rea...

Page 11: ...d or property damage always secure the CO2 cylinder with a safety chain to prevent it from falling over Should the valve become accidently damaged or broken off a CO2 regulator can cause serious perso...

Page 12: ...Probable Cause BLOWN FUSE OR CIRCUIT BREAKER A Short circuit in wiring B Defective gate solenoid C Defective agitator motor GATE DOES NOT OPEN AGITATOR DOES NOT TURN A No power B Bent depressor plate...

Page 13: ...CO2 pressure C Empty syrup tank D Kinked tubing E Clogged inner nozzle F Defective PC board G Defective harness from keypad H Defective Flow control I Defective solenoid harness J Defective keypad FLA...

Page 14: ...Ice Beverage Dispenser Operator s Manual Publication Number 92096OPR 10 2004 2014 Cornelius Inc...