AGITATION REFILL TIME ADJUSTMENT
To adjust the amount of ice chute refill agitation. begin by accessing the Extra Ice Portion Adjustment Mode (red
Indicator). Next, press and hold for the decrease and increase buttons for three seconds until the indicator flashes
amber. The indicator will flash up to four times, one flash corresponds to the minimum amount of refill agitation
and four flashes corresponds to the maximum amount of refill agitation. Change the amount of refill agitation by
pressing one of the four size buttons – the small button representing the minimum amount of refill agitation.
Increase the amount of refill agitation if the ice chute does not refill properly after dispensing ice.
To return to Normal Operation Mode, press the decrease and increase buttons at the same time.
MANUAL ICE DISPENSING OPERATION
A red pushbutton switch is provided on the upper front panel (see Figure 1) to manually dispense ice. This system
can be used for dispensing ice in portions other than cup-size or in the event of a malfunction with the ice portion
controller.
For manually dispensing ice, an auto/manual toggle switch is located adjacent to the ice portioning touch panel
(cup size selector) on the upper panel. The function of this switch is to bypass the gate solenoid valve (operated
by the portion controller) and to open the gate directly. Move the toggle switch to the “manual” position which
opens the gate immediately. Ice can now be dispensed by depressing and holding the red pushbutton switch for
the desired amount of ice. To return to the ice portioning mode of operation, move the toggle switch to the “auto”
position.
CAUTION: The gate closes immediately when the toggle switch is moved to the auto
position. Do not place fingers or foreign objects into the ice chute when operating the
toggle switch.