58
Operator's manual
Ligro - Ligro GT
with SAE15 viscosity lubricant in order to
make a drop of lubricant come out, which
can be seen from the specific cover, every 4
times the bead breaker is operated.
DANGER
Before carrying out any maintenance ope-
ration or topping
up with lubricant, discon-
nect the machine from the compressed air
supply line
.
a
b
c
e
d
35
Periodically check the lubricant level through
the specific windows and top up as shown
in fig.35c. Top up only with non-detergent
SAE15 oil equal to 50cc.
The filter regulator "FR" has an automatic
condensation drain system, therefore in con-
ditions of normal use special maintenance is
not required. The condensate may however
be drained manually at any time (fig.35d).
Normally the cups do not need to be re-
moved, but check if this is necessary for