Technical service manual
GEO 10
19
HEADS
The heads are equipped with CMOS angle sensors, inclinometer and electronic spirit level.
Electrical connections among the different devices are shown in the wiring diagram (Fig. 19).
The heads can be connected to the central unit by the included emergency cables, using
the specific connectors (A, Fig. 1) and (C, Fig. 8).
CPU head board
The measuring sensors CPU board is a micro-controllor board that acquires,
elaborates and transmits to the central unit the angles read by means of the goniometers and the
inclinometers.
The measuring sensors are assigned to the wheels of the vehicle via switches 1 and 2 of the
DIP_SWITCH PRG of the CPU board.
CONNECTOR
DESCRIPTION
JGT1
Transversal CMOS telecamera (left - right)
JGL1
Longitudinal CMOS telecamera (front - rear)
JI1
Two-axis inclinometer (Channel Y=camber, Channel X=level)
PRG
Configuration of measuring sensor position (see table)
JBATT1
Battery
Configuration of measuring sensor position by means of PRG:
PRG
1
2
3
4
Front left
OFF
OFF
OFF
OFF
Front right
ON
OFF
OFF
OFF
Rear left
ON
ON
OFF
OFF
Rear right
OFF
ON
OFF
OFF
Emergency firmware boot
X
X
X
ON
Summary of Contents for GEO 10
Page 1: ...WHEEL ALIGNER GEO 10 03 2014 SERVICE MANUAL UK...
Page 2: ......
Page 36: ...36 Technical service manual GEO 10 1 2...
Page 37: ...Technical service manual GEO 10 37 4 3...
Page 38: ...38 Technical service manual GEO 10 5 6...
Page 39: ...Technical service manual GEO 10 39 7 8...
Page 40: ...40 Technical service manual GEO 10 9 10...
Page 41: ...Technical service manual GEO 10 41 19...
Page 42: ...42 Technical service manual GEO 10 20 21...
Page 43: ...Note 43...