INSTaLLING aDDITIoNaL PW IW/a
moDULES ~ 6” 8” 10"
Position the beam correctly and connect it mechanically with the specific screws 6 fig.4
and clamp them well, paying attention to beam alignment. Connect the central casing 4
fig.4 and the power supply cables 5 fig.4, mount the left casing 1 fig.4 on the additional
module and adjust the feet 7 fig.4. The electric connection must be done following the
standards in chapter ELECTRICAL AND PNEUMATIC HOOK-UP.
ELECTrICaL aND PNEUmaTIC HooK-UP
CAUTION
All operations required for the electrical hook-up of the machine must be carried out
exclusively by qualified staff.
The electrical hook-up must be performed according to:
• absorbed power specifications indicated on the machine data plate
• the distance between the machine and the electric hook-up point, so that voltage
drops under full load do not exceed 4% (10% in the case of start-up) in comparison to
the rated voltage specified on the data plate.
- The user must:
• a dedicated power plug in compliance with the relevant electrical safety standards
• connect the machine to his own electrical socket equipped with a suitable differential
safety breaker having sensitivity of 30mA
• power line fuses in accordance with specifications in the main wiring diagram of this
manual
• a suitable earthing system installed on the workshop mains line.
- To prevent unauthorised use of the machine, always disconnect the mains plug when
the machine is not used (switched off) for extended periods of time.
- If the machine is connected directly to the power supply by means of the main electrical
panel and without the use of a plug, install a key-operated switch or suitable lock-out
device to restrict machine use exclusively to qualified personnel.
NOTE
The machine version equipped with the splicer accessory includes a pressure regulator
set to 6 bar (for standard machine use).
CAUTION
An efficient grounding circuit is essential for safe and correct machine operation.
NEVER connect the grounding line to gas or water lines, to telephone wires, or to
other non-suitable objects.
Summary of Contents for PW IW 10
Page 22: ...22 Manuale d uso PW IW 6 8 10 Note...
Page 42: ...42 User manual PW IW 6 8 10 Notes...
Page 62: ...62 Manuel d utilisation PW IW 6 8 10 Remarques...
Page 82: ...82 Betriebsanleitung PW IW 6 8 10 Anmerkungen...
Page 102: ...102 Manual de uso PW IW 6 8 10 Notas...
Page 103: ...Manual de uso PW IW 6 8 10 103 E Notas...
Page 104: ...104 Manual de uso PW IW 6 8 10 Notas...
Page 105: ...PW IW 6 8 10 105 1 2 2A...
Page 106: ...106 PW IW 6 8 10 4 3 5 6 4...
Page 107: ...PW IW 6 8 10 107 5 6 6A 6 8 3 9 2 23...
Page 108: ...108 PW IW 6 8 10 7 8 8A 20 7 7 1 5 21 4 22 23...
Page 109: ...PW IW 6 8 10 109 9 23 16 15 12 13 11 9 10 14 7 17...
Page 110: ...110 PW IW 6 8 10 10 11...
Page 111: ...PW IW 6 8 10 111 1 13 8 7 12...
Page 112: ...112 PW IW 6 8 10 1 2 14...
Page 114: ...114 PW IW 6 8 10...
Page 115: ...PW IW 6 8 10 115 Cod 4 106842...
Page 116: ...116 PW IW 6 8 10...
Page 117: ...PW IW 6 8 10 117 Cod 4 106843...
Page 118: ...118 PW IW 6 8 10 Note...
Page 119: ...PW IW 6 8 10 119 Note...
Page 123: ......