TigoMaster 2TH
– EtherNet/IP
User Manual
Copyright © 2021 CoreTigo Ltd.
Page
56
of
75
132
1 byte
Padding byte
Do not use
Padding byte
Do not use
133 …
148
16 byte
IO-Link port 8
process input
data
IO-Link input data of the
sensor/actor connected to Port
8. For a description of the data,
see manual of the manufacturer
of the used sensor/actor.
IO-Link port 8
process output
data
IO-Link output data of
the sensor/actor
connected to Port 8. For
a description of the data,
see manual of the
manufacturer of the
used sensor/actor.
149
1 byte
IO-Link Port 9
data status
0: IO-Link Port 9 input data not
valid. 1-255: IO-Link Port 9
input data valid.
IO-Link Port 9
Output enable
0: IO-Link Port 9 output
data not valid. 1-255:
IO-Link Port 9 output
data valid.
150
1 byte
Padding byte
Do not use
Padding byte
Do not use
151 …
166
16 byte
IO-Link port 9
process input
data
IO-Link input data of the
sensor/actor connected to Port
9. For a description of the data,
see manual of the manufacturer
of the used sensor/actor.
IO-Link port 9
process output
data
IO-Link output data of
the sensor/actor
connected to Port 9. For
a description of the data,
see manual of the
manufacturer of the
used sensor/actor.
167
1 byte
IO-Link Port 10
data status
0: IO-Link Port 10 input data
not valid. 1-255: IO-Link Port 10
input data valid.
IO-Link Port 10
Output enable
0: IO-Link Port 10 output
data not valid. 1-255:
IO-Link Port 10 output
data valid.
168
1 byte
Padding byte
Do not use
Padding byte
Do not use
169 …
184
16 byte
IO-Link port 10
process input
data
IO-Link input data of the
sensor/actor connected to Port
10. For a description of the
data, see manual of the
manufacturer of the used
sensor/actor.
IO-Link port 10
process output
data
IO-Link output data of
the sensor/actor
connected to Port 10.
For a description of the
data, see manual of the
manufacturer of the
used sensor/actor.
185
1 byte
IO-Link Port 11
data status
0: IO-Link Port 11 input data
not valid. 1-255: IO-Link Port 11
input data valid.
IO-Link Port 11
Output enable
0: IO-Link Port 11 output
data not valid. 1-255:
IO-Link Port 11 output
data valid.
186
1 byte
Padding byte
Do not use
Padding byte
Do not use
187 …
202
16 byte
IO-Link port 11
process input
data
IO-Link input data of the
sensor/actor connected to Port
11. For a description of the
data, see manual of the
manufacturer of the used
sensor/actor.
IO-Link port 11
process output
data
IO-Link output data of
the sensor/actor
connected to Port 11.
For a description of the
data, see manual of the