Coremorrow S51.ZT2K-C1 User Manual Download Page 6

S51.ZT2S/K-C1 Piezo Z/Tip/Tilt Platform User Manual

4

3. Product Overview  

3.1 Product Introduction

S51.ZT2S/K-C1 piezo Z/Tip/Tilt platform has the following advantages:

     High performance piezo stack:

S51.ZT2S/K-C1 is driven by a highly reliable ceramic actuator with a fully insulated 

structure, so its performance and service life are far better than the traditional actuator. 

The insulating layer can effectively prevent the piezoelectric ceramic from being damaged 

when exposed to moisture. Therefore, the stability of piezoelectric ceramics can be 

guaranteed under extreme circumstances. Compared with traditional driving mechanism, 

there are no transmission parts and friction. Therefore, ceramic actuator has the 

characteristics of no rebound, no maintenance, and no wear, etc.

     Flexible hinge structure:

S51.ZT2S/K-C1 adopts flexible hinge mechanism has advantages of no friction, high 

positioning accuracy. Flexible hinge is an element not affected by static and dynamic 

friction, based on the elastic deformation of metal material (e.g., steel) , there is no rolling 

and sliding parts. Flexible unit has very high load capacity and stiffness. Hinge guide needs 

no maintenance and no wear and tear. Suitable for a wide range of temperatures, no 

lubricating oil is required.

     Strain Sensor:

Strain sensor detects the position information by its own expansion. They are fixed in the 

proper position of the transmission part and measure the displacement of the moving 

part. This type of position measurement is made by contact and indirect measurement. So 

the displacement of the moving platform is measured by measuring lever, guide hinge, or 

piezoelectric ceramic stack.

S51.ZT2S/K-C1 is mainly used in biotechnology, interferometry, quality detection, optical 

detection, nanometer positioning, microscopy and imaging, image processing and other 

fields.3.1 Product Introduction

Summary of Contents for S51.ZT2K-C1

Page 1: ...S51 ZT2S K C1 Piezo Z Tip Tilt Platform User Manual Version V1 0 This document describes the following products S51 ZT2S C1 S51 ZT2K C1...

Page 2: ...al If you disassemble or transform the product without permission our company will not be responsible for any consequences arising therefrom To change the product model and other false sales of our co...

Page 3: ...le 5 3 3 Motion direction 6 3 4 Product Features 6 4 Operating environment 6 5 Installation and operation 7 5 1 Installation and Precautions 7 5 2 Load 7 5 3 Operating 10 6 Transportation and inspecti...

Page 4: ...Symbol and meaning DANGER Improper handling may could cause injury to the operator Attention Improper handling can cause damage to the equipment No order between items 1 3 Users of This Manual The def...

Page 5: ...ed a longer cable please contact CoreMorrow A change in temperature and pressure will charge the piezoelectric actuator and the actuator will remain energized for a period of time when it is disconnec...

Page 6: ...ble hinge mechanism has advantages of no friction high positioning accuracy Flexible hinge is an element not affected by static and dynamic friction based on the elastic deformation of metal material...

Page 7: ...5 Assume that the max control voltage is A The control mode is as follows AXIS1 x AXIS2 y Z CH1 A 2 CH2 CH3 A CH2 CH3 CH2 CH1 A CH1 CH2 CH3 CH2 CH1 CH3 AXIS2 AXIS1 PZT2 PZT3 PZT1 3 2 Control Principle...

Page 8: ...es Motion in x y and Z Closed loop version for high accuracy Fast response Aperture of 80 80mm Optional vacuum version 4 Operating environment A clean dustfree and non corrosive environment Operating...

Page 9: ...Installation and Precautions 1 Ensure that the installation plane is relatively flat 2 Mount M6 on the mounting surface directly and tighten it 3 Mounting the load and tighten it properly to ensure t...

Page 10: ...the load on one side of the moving platform which will cause serious damage to the product as shown in the figure below Excessive length of screws selected in the fastening and connecting process wil...

Page 11: ...t be too large to prevent damage to the mechanism Avoid stretching and bending cables Use the dedicated cable provided by CoreMorrow to connect S51 ZT2S K C1 and the controller Do not connect via an e...

Page 12: ...within the rated voltage range of piezoelectric ceramics 0 120V maximum 150V 5 After use please carry out voltage reset operation Please take light steps when S51 ZT2S K C1 in operation do not knock...

Page 13: ...eakage wetting dampness deformation etc Please check the completeness of package contents one by one according to the supply contract and packing list Check whether the surface of the product has obvi...

Page 14: ...tion or inaccurate positioning at startup Incorrect input control parameters Stop immediately and check the parameter Settings Resonance occurs Make drive frequency less than resonance frequency If th...

Page 15: ...face try not to pick up the product If you have to pick up the product it is better to put the sponge under the product for protection The product should not be too high from the sponge in case the pr...

Page 16: ...uum The connector interface uses 12 pin connector the model is TGG 2B 312 CLAD62Z and the wiring definition is shown in the following figure No Pin definition 1 input CH1 2 Sensor GND 3 Sensor 10V 4 D...

Page 17: ...umber The controller model Software driver version Computer operating system that installs supporting software 9 Contact us Harbin Core Tomorrow Science Technology Co Ltd Tel 86 451 86268790 Email inf...

Reviews: