background image

 

14 

  

Cooper Tools GmbH, Carl-Benz-Str. 2, 74354 Besigheim, P.O. Box 1351 

Germany, Tel: (07143) 580-0, Fax: (07143) 580108 

 

 

Autoshutter  

The camera automatically adjusts the exposure time such that an adequate image is 
displayed. On the usage of the manual shutter mode this function is automatically disabled. 
The exposure time set is displayed between the plus and minus button for the Shutter 
Mode function, with the text "Auto" (see description of the Shutter Mode function).  

Zoom  

Switches to a magnifying glass in the image area. If the left mouse button is pressed, the area around 

the magnifying glass is enlarged. If the mouse button is clicked again, the area is enlarged 
again. Using the right mouse button the zoom can be undone step-by-step. When the 
function is deactivated, the full image is displayed again    

Save  

Enables image files to be saved for documentation purposes. Visible frames are also 
saved. When the "Save" button is clicked the destination folder is displayed and the name 
of the file can be entered. When "Save" is clicked a text file is opened to which user data 
can be written. The text file is saved in the destination folder set (see Settings) under the 

same image name. The following formats are available:  

BMP format 
JPG format (default) 
 

When a file is saved a dialog box appears in which 
you can define the compression applied to the image: 
"low" highest possible compression, "best" lowest 
possible compression.   

Gamma  

The gamma value of an image is a measure of its contrast and 
brightness. By correcting the gamma value you can straightforwardly 
adjust both these variables simultaneously. The default value set is 
1.0. You can adjust the value by moving the slider or clicking the 
arrow keys. For correct analysis of the image data, a gamma of 1.0 

should always be chosen. 

 

If gamma is greater than 1.0 or less than 1.0, some of the system resources are used for performing 

this function, this will reduce the image rate.  

Gain  

You can regulate the gain of the camera signal using the slider. The 
value set is displayed. The higher the gain, the greater the noise in 
the image (interference at individual pixels) and the poorer the 
quality of the image. 
It can be necessary to increase the gain if there is insufficient light 

for the display of an adequate image (e.g. if the exposure time cannot be further increased, is 
undesirable due to the lower image rate, or if the smallest aperture is already set on the camera). 

Summary of Contents for Weller WQB OPS

Page 1: ...Camera Positioning System WQB OPS Operating Instruction Version 2 2...

Page 2: ...amera series 5 4 Description of the menu bar and the toolbar 5 4 1 Menu bar 5 4 2 Toolbar 5 5 Description of the dialog bar 6 Positioning components with the WQB 3000 OPS 6 1 Initialising the position...

Page 3: ...ponent placement The data transfer from the camera to the PC is made in real time via the IEEE 1394a interface using the OHCI protocol Distortion free pictures of the component to be placed can be ach...

Page 4: ...f the directives 89 336 EWG und 73 23 EWG 3 System requirements For the usage of the positioning system a commercial standard PC with the following features is required Intel Pentium with at least 1 G...

Page 5: ...nce with the manufacturer s instructions Choose a suitable PCI expansion slot Unscrew the cover plate for the slot Insert the FireWire interface card in an empty PCI slot in the PC Press the adapter g...

Page 6: ...ssing software 4 4 1 Installation of the driver for the FireWire interface card Insert installation CD in the drive on the PC Open Hardware wizard on the PC START MY COMPUTER PROPERTIES HARDWARE DEVIC...

Page 7: ...fter the installation Proceed as follows Has the interface card been fitted to the PC in accordance with the instructions Is the camera connected Is the camera connecting cabled inserted Has the image...

Page 8: ...e general functions for using the program The individual commands are described in section 5 4 1 Toolbar Here you will find buttons for using the program This toolbar can be toggled on and off The ind...

Page 9: ...t and click the OK button The selected camera is then always opened each time the program is started Following camera types are supported CX05c Colour Digital camera with standard resolution CX13c Col...

Page 10: ...eletes the component with a blue background Edit Opens the Edit Component dialog box in which you can change the entries for the selected component Cancel Closes the dialog box without accepting the c...

Page 11: ...is commissioned for the first time Proceed as follows Insert calibration plate in the WQB 3000 circuit board holder Lock soldering head in the centre of the unit and align the cross wires on the calib...

Page 12: ...d to which user data can be written The text file is saved in the destination folder set see Settings under the same image name The image formats BMP and JPG default are available see also Save in the...

Page 13: ...y positioned around the positioning cross If a calibration has not been performed following installation this button is not available The size of the frame depends on the data for the component select...

Page 14: ...n the destination folder set see Settings under the same image name The following formats are available BMP format JPG format default When a file is saved a dialog box appears in which you can define...

Page 15: ...must be positioned on the first scale point required and the cross set by clicking the left mouse button Keep the mouse button pressed and drag to the second scale point When the cross is in exactly t...

Page 16: ...ed and the RGB colour values red green and blue can be changed individually by the user These functions are only available for colour cameras to change the RGB colour values Enable must be selected If...

Page 17: ...4 x 25 63 x 47 3 0 26 24 x 18 18 x 13 34 x 25 The objective 3 together with the camera 1 is bolt to the base unit with the clamping ring 14 6 1 2 Selecting the vacuum insert 2 different vacuum inserts...

Page 18: ...he positioning frames During the calibration a conversion factor from image dots in the camera pixels to a measure of length mm is calculated The calibration process is explained in more detail in the...

Page 19: ...a time delay the vacuum will be switched off and the positioning unit is lifted upwards The component is now exactly placed on the circuit board With the aid of the operating lever 2 the placement he...

Page 20: ...of any displayed positioning frame didn t lay exactly on the diagonals of the calibration tool Repeat the Camera Adjustment command once more The adjustment must be made with great care by a suitable...

Page 21: ...The linear guides on the positioning unit are lubricated for life in the factory and do not required any further care 7 3 2 Repair and upkeep Repairs on the positioning system are allowed to do only...

Page 22: ...25 Hz 1 3 Progressive Scan 1034 x 776 4 6 x 4 6 m2 19 Hz 2 3 Progressive Scan 1392 x 1040 6 7 x 6 7 m2 15 Hz Colour filter RGB Bayer Matrix Optical Interface Objective C Mount Ambient conditions Opera...

Page 23: ...ng lever 3 Telecentrical objective 4 Positioning unit 5 Precision drive x adjustment 6 Precision drive y adjustment 7 Connecting screw rotating ring 8 Operating lever theta adjustment 9 LED illuminati...

Reviews: