www.cooperbussmann.com/wirelessresources
Cooper Bussmann 615M-1 Cellular Data Modem and IP Router Series Manual
49
Rev Version 1.0
Figure 30 Diagnostics–SNMP
SNMP Configuration
SNMP
Selecting “Enable” allows SNMP functionality. Selecting “Disable” turns off SNMP
functionality.
Version
With SNMP enabled, select the corresponding version that matches the SNMP
manager.
SNMP v2c
Read-only
Community Name
The community string used for accessing the read-only Management Information
Bases (MIBs).
Read-write
Community Name
The community string used for accessing all Management Information Bases (MIBs)
including writable objects.
SNMP v3
User Name
The user name for secure access to the Management Information Bases (MIBs)
observing v3 standard.
Password
The corresponding user password for accessing the Management Information Bases
(MIBs), including writable objects.
Authentication
Sets the authentication method for accessing the Management Information Bases
(MIBs).