Cooper Bussmann 5073E-T Managed Ethernet Switch User Manual
Rev Version 1.1
System Restart
When enabled, the system will issue an alert to the system log server when the
device executes a cold start. It may take a minute after the cold start before the event
appears in the system log server.
Power Status
When enabled, the system will issue an alert to the system log server when input
power to the switch becomes unstable.
SNMP Authentication
Failure
When enabled, the system will issue an alert to the system log server when SNMP
authentication fails.
Apply
Click to apply the setting.
Digital Input/Digital Output
The 5073E-T Switch contains two digital outputs and two digital inputs. Outputs are open-collector transistor
switches that may be controlled by the host computer. They provide control signals, which can be applied to
heaters, pumps, and other electrical equipment. The digital inputs may be read by the host computer and used to
detect the state of a remote digital signal.
Figure 39 Digital Input