MODELS • 

I

L90LA1151 • 

I

L150LA1151

SERVICE PARTS

SERVICE PARTS

KEY NO.

PART NO.

DESCRIPTION

1

97014853

Damper Flap

2

99150415

Screw, #8B x ¼* (16 req.)

3

98009520

Duct Connector (2 req.)

4

97014784

Housing Assembly

5

97014728

Mounting Bracket (2 req.)

6

99150591

Mounting Screw (4 req.)

7

97006142

Wiring Harness

8

99150471

Ground Screw, #10-32 x ½* (2 req.)

9

98005512

Wiring Adapter Plate

10

99420470

Access Panel Nut (4 req.)

11

98009531

Movable Housing Panel

12

93150487

Screw, #10-24 x .375* (8 req.)

13

98005513

Outlet Box Cover

14

99400035

Strain Relief Bushing

15

97014788

Motor Bracket

16

99260477

Whiz Nut, ¼-20* (11 req.)

17

99200202

Screw, ¼-20 x ½* (5 req.)

18

97014785

Blower Scroll

19

99080490

Motor (

I

L90LA1151)

99080491

Motor (

I

L150LA1151)

20

93260447

Nut, Hex Flange 5/16-18* (5 req.)

21

98009516

Support Bracket

22

99680019

Wheel Clamp

23

99020274

Blower Wheel (Includes Key No. 22)

24

98009514

Inlet Ring

25

99150417

Screw, #8-18 x ¼* (5 req.)

26

98009513

Scroll Support Channel

+

97014848

Blower Assembly Complete (

I

L90LA1151)

(Includes Key Nos. 15 thru 26)

+

97014849

Blower Assembly Complete (

I

L150LA1151)

(Includes Key Nos. 15 thru 26)

27

98009532

Access Cover

28

99150472

Access Cover Screw (4 req.)

Order replacement parts by PART NO. - not by KEY NO.
* Standard hardware - may be purchased locally.
+ Not shown assembled.

1

2

3

5

6

7

2

8

9

12

10

14

15

16

17

18

21

16

4

22

13

19

23

20

24

17

26

27

28

3

11

16

25

2

BLOWER

ASSEMBLY

WARRANTY

99042884B

Limited Warranty

In the sale of its products, American Coolair Corporation agrees to correct, by repairs or replacement, any defects in workmanship or material
that may develop under proper and normal use during the period of one year from date of shipment from factory. Any product or part proving,
upon American Coolair’s examination, to be defective during limited warranty period will be repaired or replace, at American Coolair’s option,
f.o.b. factory, without charge.

Deterioration or wear caused by chemicals, abrasive action or excessive heat shall not constitute defects.

Motors are guaranteed only to the extent of manufacturer’s warranty.

American Coolair’s limited warranty does no apply to any of its products or parts that have been subject to accidental damage, misuse by the
user, unauthorized alterations, improper installation or electrical wiring, or lack of proper lubrication of other service requirements established by
American Coolair.

Repairs or replacements provided under the above terms shall constitute fulfillment of all American Coolair’s obligations with respect to limited
warranty.

THE LIMITED WARRANTY STATED HEREIN IS IN LIEU OF ALL OTHER WARRANTIES. EXPRESS, STATUTORY OR IMPLIED, INCLUDING
WITHOUT LIMITATION THAT OF MERCHANTABILITY AND FITNESS.

NO LIABILITY FOR REINSTALLATION COST OF FOR ANY SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES OF ANY NATURE IS
ASSUMED OR SHALL BE IMPOSED UPON AMERICAN COOLAIR.

AMERICAN COOLAIR CORP. / ILG INDUSTRY, 3604 MAYFLOWER ST.
JACKSONVILLE, FLORIDA 32205, TEL: 904-389-3646

Summary of Contents for IL90LA1151

Page 1: ... other hidden utilities 6 Ducted fans must always be vented to the outdoors 7 To reduce the risk of fire use only metal ductwork 8 If this unit is to be installed over a tub or shower it must be marked as appropriate for the application and be connected to a GFCI Ground Fault Interrupter protected branch circuit 9 Never place a switch where it can be reached from a tub or shower 10 This unit must ...

Page 2: ...uctwork to a factory shipped unit Ventilator can be wired from outside of housing Use UL approved connectors to wire per local codes ROOF CAP 12 ROUND ELBOW 12 ROUND DUCT WALL CAP IMPORTANT Remove shipping tape from damper Remove the shipping tape from the damper flap and make sure that damper flap opens and closes freely inside the ductwork Use duct tape to make ductwork connections secure and ai...

Page 3: ...efore servicing To clean blower assembly Remove access panel unplug blower from housing remove blower mounting nuts and carefully remove blower from housing Use appropriate vacuum attachment or a soft cloth and mild soap or detergent to clean blower discharge area and wheel DO NOT ALLOW WATER TO ENTER MOTOR Make sure blower assembly is completely dry before reinstalling Motor is permanently lubric...

Page 4: ...ER ASSEMBLY WARRANTY 99042884B Limited Warranty In the sale of its products American Coolair Corporation agrees to correct by repairs or replacement any defects in workmanship or material that may develop under proper and normal use during the period of one year from date of shipment from factory Any product or part proving upon American Coolair s examination to be defective during limited warrant...

Page 5: ...es donduits de ventilation en métal 8 Si cette unité doit être installée au dessus d une baignoire ou d une douche elle doit être marquée comme étant appropriée pour l application et être connectée à un circuit dérivé protége GFCI interrupteur de circuit en cas de défaut de mise à la terre du neutre 9 Ne placez jamais un interrupteur dans un endroit où il peut être rejoint d une baignoire ou d une...

Page 6: ...ur assurer et étancher les raccords des conduits TRANSITION CIRCULAIRE 8 x 12 po 20 3 x 30 5 cm AU 12 po 30 5 cm CHAPEAU DE TOIT COUDE CIRCULAIRE DE 12 po 30 5 cm CHAPEAU DE MUR CONDUIT CIRCULAIRE DE 12 po 30 5 cm TRANSITION DE 8 x 12 po au 12 po circulaire 20 3 x 30 5 cm au 30 5 cm circulaire SOLIVE DE PLAFOND 24 po 61 cm centre CONDUIT CIRCULAIRE DE 12 po 30 5 cm sortie PANNEAU D ACCESS Souffler...

Page 7: ...lisation continue Si désiré il peut être commandé à l aide d un interrupteur marche arrêt ou d un régulateur de vitesse à semi conducteurs Suivre les instructions de câblage fournies avec le régulateur et respecter tous les codes locaux et provinciaux en vigueur de même que le Code national de l électricité Supports en position préassemblée Sortie parallèle aux solives Bâtiment en cours de con str...

Page 8: ... ses produits American Coolair Corporation s engage à corriger par une réparation ou un remplacement tout vice de matériau ou de fabrication étant apparu dans des conditions normales et adéquates d utilisation durant une période d un an à compter de la date d expédition du produit de l usine Tout produit ou pièce qui suite à l examen d American Coolair s avère défectueux durant la période de garan...

Reviews: