Coolair IL90LA1151 Instructions Manual Download Page 2

Page 2

MODELS • 

I

L90LA1151 • 

I

L150LA1151

TYPICAL INSTALLATION

MOUNTING

(New Frame Construction)

CEILING

JOIST

(24”

centers
shown)

12” ROUND

DUCT

(OUTLET)

ACCESS

PANEL

Factory-shipped unit installed in new construction.

MOUNTING

SCREWS

ACCESS

PANEL SCREW

Ventilator factory-shipped

in straight-through

discharge position.

MOUNTING

BRACKETS

MOUNTING

(Existing Frame Construction)

Factory-shipped unit installed in existing construction.

TYPICAL INSTALLATION

WIRING

WIRING

PLATE

WHITE

TO

WHITE

BLACK

TO

BLACK

EDGE

OF HOUSING

120 VAC LINE IN

GROUND TO

WIRING PLATE

ACCESS

PANEL

SCREW

DUCTING

(Straight-through blower discharge)

Two ways to connect ductwork to a factory-shipped unit.

Ventilator can be wired from outside of housing.

Use UL approved connectors to wire per local codes.

ROOF CAP

12” ROUND

ELBOW

12”

ROUND

DUCT

WALL

CAP

IMPORTANT:
Remove shipping tape from damper

Remove the shipping tape from the damper flap and make sure
that damper flap opens and closes freely inside the ductwork. Use
duct tape to make ductwork connections secure and air-tight.

8” X 12”

TO

12” ROUND

TRANSITIONS

8” X 12” TO 12” ROUND

TRANSITIONS

12” ROUND DUCT

(OUTLET)

FINISHED

CEILING

MATERIAL

Ventilator

factory-shipped

in straight-through

discharge position.

MOUNTING

BRACKETS

8” X 12” TO

12” ROUND

TRANSITIONS

CEILING

JOIST

(24” centers

shown)

ACCESS PANEL

12” ROUND

DUCT

(INTAKE)

12” ROUND

DUCT (INTAKE)

12”

ROUND

DUCT

GRILLE NUT

(Install into square

holes in housing)

GRILLE NUT

(Install into

square holes in

housing)

Summary of Contents for IL90LA1151

Page 1: ... other hidden utilities 6 Ducted fans must always be vented to the outdoors 7 To reduce the risk of fire use only metal ductwork 8 If this unit is to be installed over a tub or shower it must be marked as appropriate for the application and be connected to a GFCI Ground Fault Interrupter protected branch circuit 9 Never place a switch where it can be reached from a tub or shower 10 This unit must ...

Page 2: ...uctwork to a factory shipped unit Ventilator can be wired from outside of housing Use UL approved connectors to wire per local codes ROOF CAP 12 ROUND ELBOW 12 ROUND DUCT WALL CAP IMPORTANT Remove shipping tape from damper Remove the shipping tape from the damper flap and make sure that damper flap opens and closes freely inside the ductwork Use duct tape to make ductwork connections secure and ai...

Page 3: ...efore servicing To clean blower assembly Remove access panel unplug blower from housing remove blower mounting nuts and carefully remove blower from housing Use appropriate vacuum attachment or a soft cloth and mild soap or detergent to clean blower discharge area and wheel DO NOT ALLOW WATER TO ENTER MOTOR Make sure blower assembly is completely dry before reinstalling Motor is permanently lubric...

Page 4: ...ER ASSEMBLY WARRANTY 99042884B Limited Warranty In the sale of its products American Coolair Corporation agrees to correct by repairs or replacement any defects in workmanship or material that may develop under proper and normal use during the period of one year from date of shipment from factory Any product or part proving upon American Coolair s examination to be defective during limited warrant...

Page 5: ...es donduits de ventilation en métal 8 Si cette unité doit être installée au dessus d une baignoire ou d une douche elle doit être marquée comme étant appropriée pour l application et être connectée à un circuit dérivé protége GFCI interrupteur de circuit en cas de défaut de mise à la terre du neutre 9 Ne placez jamais un interrupteur dans un endroit où il peut être rejoint d une baignoire ou d une...

Page 6: ...ur assurer et étancher les raccords des conduits TRANSITION CIRCULAIRE 8 x 12 po 20 3 x 30 5 cm AU 12 po 30 5 cm CHAPEAU DE TOIT COUDE CIRCULAIRE DE 12 po 30 5 cm CHAPEAU DE MUR CONDUIT CIRCULAIRE DE 12 po 30 5 cm TRANSITION DE 8 x 12 po au 12 po circulaire 20 3 x 30 5 cm au 30 5 cm circulaire SOLIVE DE PLAFOND 24 po 61 cm centre CONDUIT CIRCULAIRE DE 12 po 30 5 cm sortie PANNEAU D ACCESS Souffler...

Page 7: ...lisation continue Si désiré il peut être commandé à l aide d un interrupteur marche arrêt ou d un régulateur de vitesse à semi conducteurs Suivre les instructions de câblage fournies avec le régulateur et respecter tous les codes locaux et provinciaux en vigueur de même que le Code national de l électricité Supports en position préassemblée Sortie parallèle aux solives Bâtiment en cours de con str...

Page 8: ... ses produits American Coolair Corporation s engage à corriger par une réparation ou un remplacement tout vice de matériau ou de fabrication étant apparu dans des conditions normales et adéquates d utilisation durant une période d un an à compter de la date d expédition du produit de l usine Tout produit ou pièce qui suite à l examen d American Coolair s avère défectueux durant la période de garan...

Reviews: