Coolair IL90LA1151 Instructions Manual Download Page 3

Page 3

MODELS • 

I

L90LA1151 • 

I

L150LA1151

;;;;;;;;;

yyyyyyyyy

18"

1½"

to

2½"

;;;

;;;

@@@

@@@

;;;

;;;

@@@

@@@

;;;

;;;

@@@

@@@

;;;

;;;

@@@

@@@

;;;

;;;

@@@

@@@

;;;

;;;

@@@

@@@

;;;

;;;

yyy

yyy

;;

@@

;;

@@

;;

@@

;;

@@

;;

@@

;;

@@

;;

yy

;;;;;;;;;

yyyyyyyyy

18"

1½"

to

2½"

;;;

;;;

@@@

@@@

;;;

;;;

@@@

@@@

;;;

;;;

@@@

@@@

;;;

;;;

@@@

@@@

;;;

;;;

@@@

@@@

;;;

;;;

@@@

@@@

;;;

;;;

yyy

yyy

;;

@@

;;

@@

;;

@@

;;

@@

;;

@@

;;

@@

;;

yy

;;;

yyy

;;;

yyy

22"

;

y

;;;

yyy

22"

1

1

/

8

"

MAX.

MOUNTING OPTIONS

WIRING OPTIONS

DUCTING OPTIONS

Mounting brackets in

factory-shipped position -
mounted directly to joists.

(Outlet parallel to joists.)

(New construction)

¼-20 hex nuts secure mounting brackets to housing. Loosen and
re-tighten or remove and replace nuts as necessary for desired
mounting bracket position.

Mounting brackets flipped

over and mounted to

additional framing.

(Outlet perpendicular to joists.)

(New or Existing construction)

BLOWER DISCHARGE POSITIONS

WIRING PLATE
POSITION

Wiring plate mounts to side or top of housing.

HORIZONTAL POWER
CABLE CONNECTION

VERTICAL

POWER

CABLE

CONNECTION

Ventilator shown in

straight-through discharge

position. (Factory shipped)

DUCT

CONNECTOR

(intake)

Ventilator shown in right-

angle discharge position.

(Change movable panel to

new location as shown.)

MOVABLE

PANEL

DUCTING

(Vertical blower discharge)

Typical ductwork connection to a ventilator converted to

right-angle discharge.

ROOF CAP

12” ROUND

DUCT

WARNING: To reduce the risk of electric shock,
disconnect from power supply before servicing.

To clean blower assembly:

 Remove access panel, unplug blower

from housing, remove blower mounting nuts, and carefully remove
blower from housing. Use appropriate vacuum attachment or a soft
cloth and mild soap or detergent to clean blower discharge area
and wheel. DO NOT ALLOW WATER TO ENTER MOTOR. Make
sure blower assembly is completely dry before reinstalling.

Motor is permanently lubricated. Do not oil or disassemble motor.

USE AND CARE

Ventilator is designed for continuous operation. If desired, it may be
controlled using an on/off switch or a solid-state, variable speed
control. Follow wiring instructions packed with control, and adhere
to all local and state codes, and the National Electrical Code.

Factory-Shipped

Straight-Through

Discharge

Factory-Shipped

Straight-Through

Discharge

Housing

Converted to

Right-Angle

Discharge

Mounting brackets flipped

over and mounted to

additional framing.

(Outlet vertical.)

(New or Existing construction)

Mounting brackets flipped

over and mounted to top of

housing. Housing secured

with cables.

(Outlet parallel to joists.)

(New or Existing construction)

Factory-Shipped

Straight-Through

Discharge

MOVABLE

PANEL

(Change to this

location)

8” X 12” TO

12” ROUND TRANSITIONS

DUCT

CONNECTOR

(outlet)

DUCT

CONNECTOR

(intake)

DUCT

CONNECTOR

(outlet)

Housing
rotated &
movable panel
covers previous
open side.

12” ROUND

DUCT

Summary of Contents for IL90LA1151

Page 1: ... other hidden utilities 6 Ducted fans must always be vented to the outdoors 7 To reduce the risk of fire use only metal ductwork 8 If this unit is to be installed over a tub or shower it must be marked as appropriate for the application and be connected to a GFCI Ground Fault Interrupter protected branch circuit 9 Never place a switch where it can be reached from a tub or shower 10 This unit must ...

Page 2: ...uctwork to a factory shipped unit Ventilator can be wired from outside of housing Use UL approved connectors to wire per local codes ROOF CAP 12 ROUND ELBOW 12 ROUND DUCT WALL CAP IMPORTANT Remove shipping tape from damper Remove the shipping tape from the damper flap and make sure that damper flap opens and closes freely inside the ductwork Use duct tape to make ductwork connections secure and ai...

Page 3: ...efore servicing To clean blower assembly Remove access panel unplug blower from housing remove blower mounting nuts and carefully remove blower from housing Use appropriate vacuum attachment or a soft cloth and mild soap or detergent to clean blower discharge area and wheel DO NOT ALLOW WATER TO ENTER MOTOR Make sure blower assembly is completely dry before reinstalling Motor is permanently lubric...

Page 4: ...ER ASSEMBLY WARRANTY 99042884B Limited Warranty In the sale of its products American Coolair Corporation agrees to correct by repairs or replacement any defects in workmanship or material that may develop under proper and normal use during the period of one year from date of shipment from factory Any product or part proving upon American Coolair s examination to be defective during limited warrant...

Page 5: ...es donduits de ventilation en métal 8 Si cette unité doit être installée au dessus d une baignoire ou d une douche elle doit être marquée comme étant appropriée pour l application et être connectée à un circuit dérivé protége GFCI interrupteur de circuit en cas de défaut de mise à la terre du neutre 9 Ne placez jamais un interrupteur dans un endroit où il peut être rejoint d une baignoire ou d une...

Page 6: ...ur assurer et étancher les raccords des conduits TRANSITION CIRCULAIRE 8 x 12 po 20 3 x 30 5 cm AU 12 po 30 5 cm CHAPEAU DE TOIT COUDE CIRCULAIRE DE 12 po 30 5 cm CHAPEAU DE MUR CONDUIT CIRCULAIRE DE 12 po 30 5 cm TRANSITION DE 8 x 12 po au 12 po circulaire 20 3 x 30 5 cm au 30 5 cm circulaire SOLIVE DE PLAFOND 24 po 61 cm centre CONDUIT CIRCULAIRE DE 12 po 30 5 cm sortie PANNEAU D ACCESS Souffler...

Page 7: ...lisation continue Si désiré il peut être commandé à l aide d un interrupteur marche arrêt ou d un régulateur de vitesse à semi conducteurs Suivre les instructions de câblage fournies avec le régulateur et respecter tous les codes locaux et provinciaux en vigueur de même que le Code national de l électricité Supports en position préassemblée Sortie parallèle aux solives Bâtiment en cours de con str...

Page 8: ... ses produits American Coolair Corporation s engage à corriger par une réparation ou un remplacement tout vice de matériau ou de fabrication étant apparu dans des conditions normales et adéquates d utilisation durant une période d un an à compter de la date d expédition du produit de l usine Tout produit ou pièce qui suite à l examen d American Coolair s avère défectueux durant la période de garan...