7
Status LED and Valet Switch
PROGRAM OVERRIDE SWITCH: 2 PIN PLUG (REQUIRED FOR PROGRAMMING & LEARNING REMOTES)
This is a multi-function switch used for programming options, transmitters, Valet mode.
LED: 2 PIN PLUG
The LED is used for Remote Start Diagnostics and a Valet indicator. It will also flash for use as security deterrent.
VALET / PROGRAM SWITCH
STATUS LED
“SMART TACHLESS” MODE
Your Data Start system includes a unique voltage monitor called “Smart Tachless” mode. This mode allows this unit to
efficiently start an engine without the use of a tach signal wire. This module actively monitors the voltage level of the
vehicle to control the starter motor each time a remote start is requested.
IMPORTANT NOTES:
(1) On the rare occasion that “Smart Tachless” mode does not operate satisfactorily, change the voltage reference level
as described below, or use a different mode such as “Tach” mode, or “Timed Crank” mode.
“SMART TACHLESS” ADJUSTMENT: Option # 21
In the event “Smart Tachless” over-cranks or under-cranks your starter, the settings can be changed. The purpose of
adjusting the “Smart Tachless” Mode is to raise or lower the voltage reference threshold from the 93% default point.
Raising or lowering this 93% point should increase or decrease your cranking time respectively. The adjustment range is
from 79% to 100% in one percent increments. This requires a 4 button remote to change reference.