ENGLISH
Thank you for having chosen one of our products. You certainly have made a good investment and we are sure that our appliance will prove this
to you. Our appliance have been carefully designed to give the best possible performances under the best safe and economic conditions. Many
strict controls have been carried out during production process.
Please follow carefully the here under instructions to avoid end user risks, unit damages or compromise the unit performance.
Our company decline all responsibilities whereas the original good performances of the unit would get worse because of any
kind of modification (any adding or taking away of electrical or mechanical parts) or for not having strictly followed the
instructions given in this run book. This run book has to be well kept and given to any eventual new user.
INSTALLATION
Take out packing and clean all the cabinet following the instruction given in point 5 Maintenance then:.
1.
Do not install the unit in open spaces and repaired from rain. The functioning is regular with the ambient temperature and conditions
indicated on the technical data plate, placed inside the tank
2.
The cabinet has to be installed on a plane surface and it must be perfectly levelled: to obtain this the adjustable feet.
3.
Place the cabinet away from air streams and far away from heating sources (radiators, cookers) and not directly exposed to the sun. To
light the room where the cabinet is placed we do suggest to use fluorescent lamp
4.
The cabinet must never lean against the wall: the back aeration grill must have an open space. Keep a distance of at least 10 cm between
the wall and the cabinet. Always unplug the cabinet before moving it. You have to keep the same distance between the cabinet sides and
other piece of furniture.
5.
Check that the cabinet is not been damaged during the transport.
6.
Do not leave objects on the equipment, such as containers, plants, etc. and leave at least 50 cm of free space above the equipment
.
7.
The use of this equipment by children or people with physical, sensorial, mental or motion disability, or people who do not have the
necessary knowledge and experience, could lead to dangerous situations. The people responsible for their safety should give them explicit
instructions or check the use of this equipment;
8.
Make sure that children do not play with the equipment.
MODEL 250 - INSTALLATION FOR SINGLE-PHASED POWER SUPPLY
The wall is equipped with power supply cable 5 x 2.5 sq. mm., indicated for three-phased power supply with neutral.
Follow these operations to connect the device to the single-phased 230 V network.
Connect the 3 phases (black, brown, gray cables) together, by connecting them directly to a bi-polar differential-magnetothermal switch In =
20 A, Id = 30 mA.
Connect the pale blue cable (neutral) to the other terminal of the switch.
Connect the yellow-green cable (earth) to the earth terminal.
!!!ATTENTION!!!
DO NOT WET THE CABINET PARTS WHERE ELECTRIC COMPONENTS ARE PRESENT. DO NOT FORCE ANY
PART OF THE CABINET WHERE THERE IS THE REFRIGERATING CIRCUIT.
THE CABINET IS NOT SUITABLE FOR WORKING IN DANGEROUS PLACES WITH RISK OF FIRE,
EXPLOSIONS AND/OR RADIATION.
Check that the actual network voltage corresponds to the one stated on the technical data plate . Do not lay
anything on the cabinet (plants, boxes, etc..) and leave a free space of minimum 50 cm. over the cabinet.
The electric line where the unit will be connected must be protected by any high sensitivity differential switch
(In=16A,Id=30mA) and connected to general earthling.
THE EARTHLING OF THE INSTALLATION IS A SAFETY STANDARD WHICH IS ENFORCED BY LAW. OUR
COMPANY HAS PROVIDED FOR THIS CONNECTION ACCORDING TO THE EXISTING STANDARDS AND
THEREFORE WE DECLINE ANY RESPONSIBILITY FOR POSSIBLE DAMAGES TO PEOPLE OR THINGS.
WARNING!!
Do not place the feeding cable in contact with asperities, smudging or edges or with high temperature
parts. Please arrange the feeding cable to NOT retract in the motor cage grill, it could be damaged.
For plugging do not absolutely use any reduction or multiple current-tap.
CAUTION
THIS SYMBOL INDICATES THAT ONLY AUTHORISED AND TRAINED TECHNICIANS SHALL CARRY OUT THE
OPERATION:
Trained and skilled operator, aware of risks involved and responsible of adopting all measures necessary
to minimise any possible damage to himself and other people.
!!!! CAUTION !!!!
ONLY SPECIALISED TECHNICIANS SHALL CARRY OUT THIS OPERATION