20
Picture 4: Top view of solid waste refrigerator
6. TROUBLE SHOOTING
The solid waste refrigerators are designed and produced for a long life and
trouble free function. Alarm messages are displayed flashing and indicated by
means of an acoustic signal. To stop the alarm signal see page 17. Should
nevertheless a malfunction occur, please check as follow:
Trouble/Error message
Measures
Dark Display
- Check electrical current supply
(fuse, socket)
Alarm HI
Requested temperature is not
reached
- Check set rated value
- Doors closed properly?
- Waste stored properly?
(see chapter 4)
- Defrost iced evaporator (remove
waste containers and switch off
until evaporator is ice-free)
Alarm HO
Device too cold
- Check set rated value
- Switch off device, pull mains plug
and switch on again after approx.
2 minutes
Electronic controller
with digital display
Clean condenser
(ribs) here
Condensation
channel and drain
Throw-in flap
Type
plate
Summary of Contents for AAKM Series
Page 42: ...42 42 ...