2-22
1010PVNFM-3A
Section 2
NOTE: Menu cell [Install Path] appears when the Dual Path Flow meter is selected
from the [Select Meter Type] menu. The Path [1] or Path [2] menu cell can be
selected by pressing the <Right Arrow>.
Pick/Install Xdcr
Transducer Model
991 Universal
1011 Universal
1011 Hi Precision
Transducer Size
A1
A1
0A
0A
A1H
A1H
A2
0
A2H
B1
1
A3H
B2
2A
B1H
B3
2
B2H
C1
3A
B3H
C2
3
C1H
C3
4A
C2H
D1
4
D1H
D2
5A
D2H
D3
5
D3H
E1
D4H
E2
E3
Xdcr Mount Mode
Direct
Reflect
Spacing Offset
Minimum
Nominal
Maximum
Number Index
4
(generated)
Spacing Method
Spacer Bar [P/N]
*
auto P/N generation
Ltn Value (in)
2.00 (generated)
Install Completed
No [Yes]
*[Yes] indicates successful install
Install
Empty Pipe Set
MTYmatic
Set Empty
Actual MTY
Zero Flow Adjust
AutoZero
*Reflect mount only
ZeroClr
Reversamatic
Actual Zero
ZeroMatic
1011 Universal
991 Universal
1011H High Precision
ô
ð
ð
ð
ð
ô
ô
ô
ô
ô
ô
ô
ô
ô
ð
ð
ð
ð
ð
ð
ô
ô
ô
ô
ð
ð
ô
PICK/INSTALL XDCR MENU STRUCTURE
2.4.1 HOW TO SELECT A TRANSDUCER MODEL
Use the [Transducer Model] menu cell to define the type of transducer for use with your
application. This allows the flow computer to adjust its transmit/receive functions accord-
ingly. You can choose from either the [1011 Universal] or [1011H High Precision] transducer
lists, or from a list of [991 Universal] models. You should consider using high precision trans-
ducers for extremely critical applications. We usually recommend these transducers for cus-
tody transfer, leak detection or nuclear power applications. The system default is [1011 Uni-
versal]. If this suits the application, bypass this menu cell by pressing the <Down Arrow>.