![Controlotron 1010PVDN Field Manual Download Page 43](http://html1.mh-extra.com/html/controlotron/1010pvdn/1010pvdn_field-manual_2658905043.webp)
2-11
1010PVNFM-3A
Section 2
NOTE: Do not use ASA schedule code to specify the wall thickness. You must enter
actual dimensions.
To enter the Pipe Wall Thickness:
To enable numeric entry press
Use the keypad’s numeric keys to type exact wall thickness (use in/mm).
To register the pipe wall thickness press
2.2.6 LINER MATERIAL
For lined pipes, select a pipe liner from the material option list. If the pipe liner material
does not appear on the list then select the closest type available. If necessary, call Contro-
lotron Customer Service for additional help. The system default Liner Material is [None]. If
the pipe does not have a liner, press the <Down Arrow> twice to bypass to the next two menu
cells. The [Liner Material] option list offers a selection of common liner materials.
To select a Liner Material:
To access the [Liner Material] option list press
To scroll to the required Liner material press
To register selection press
2.2.7 LINER THICKNESS
If you specified a pipe liner in the [Liner Material] menu cell, then use this menu cell to set its
exact thickness in appropriate units (English or Metric).
To enter a Liner Thickness:
To enable numeric entry press
Use the number keys to type the exact line thickness value.
To register the data press
2.2.8 ThermExp Coef
Use this menu cell to set the Thermal Expansion Coefficient.
To enter the Thermal Expansion Coefficient value:
To enable numeric entry press
Use the number keys to type the Thermal Coeffiecient value.
To register the data press
ENT
ENT
ENT
ENT