SM-Universal Encoder Plus User Guide
81
Issue Number: 6
www.controltechniques.com
drive (see Pr
x.18
), in Pr
x.11
. The comms resolution may be higher than the resolution
of the sine waves per revolution.
Ab, Fd, Fr, Ab.SErvo, Fd.SErvo, Fr.SErvo, SC, SC.SErvo
Pr
x.11
has no effect.
SC.HiPEr, SC.EndAt, SC.SSI and x.16 = 1 or 2 (Rotary encoder)
Pr
x.11
must be set to the number of comms bits used to represent one revolution of the
encoder. The single turn comms resolution may be higher than the resolution of the sine
waves per revolution.
SC.HiPEr, SC.EndAt, SC.SSI and x.16 = 0 (Linear encoder)
Pr
x.11
must be set up to the total number of bits representing the whole encoder
position in the comms message.
This parameter is not used with linear SC.HiPEr encoders as the number of bits used to
represent the whole position is always 32.
EndAt, SSI
Pr
x.11
must be set to the number of bits used to represent one revolution of the
encoder.
Although Pr
x.11
can be set to any value from 0 to 32, if the value is less than 1, the
resolution is 1 bit. Some SSI encoders (SC.SSI or SSI) include a power supply monitor
alarm using the least significant bit of the position. It is possible for the drive to monitor
this bit and produce a trip 6 if the power supply is too low (see Pr
x.17
). If the encoder
gives this information the comms resolution should be set up to include this bit whether
it is being monitored by the Solutions Module or not.
It is possible for the drive to set up this parameter automatically from encoder
information via Hiperface or EndAt interfaces (see Pr
x.18
).
The motor thermistor if connected to the Solutions Module for temperature monitoring is
enabled through this parameter.
on page 55 for full details.
The encoder supply voltage present on the SM-Universal Encoder is defined by this
parameter as 0(5V), 1(8V), or 2(15V).
This parameter defines the baud rate for the encoder comms when using encoders with
either SSI or EndAt interfaces. A fixed baud rate of 9600 is used with Hiperface
x.12
Motor thermistor check enable
RW
Bit
US
Ú
OFF (0) or On (1)
Ö
OFF (0)
Update rate: Background read
x.13
Encoder supply voltage
RW
Uni
US
Ú
0 to 2
Ö
0
Update rate: Background read
x.14
Encoder comms baud rate
RW
Txt
US
Ú
0 to 7
Ö
2
Update rate: Background read