TECHNICAL FEATURES 

MEASURES, PRECISIONS 
voltage 

true RMS of the phase voltages and the phase to phase voltages and values of three phase system 
range of total measure: 20÷500V trms phase-phase - 290V rms phase-neutral dependent by the auxiliary 
power supply 
visualization (0,02÷50,0kV)  -  measure precision: ±0,5% ±1 digit– management maximum values 

current 

true RMS of the phase currents and of the value of three phase system 
range of measure: 0,02÷5A trms   -  measure precision: ±0,5% ±1 digit 
visualization 0,02÷9990A – management average and maximum values 

frequency 

frequency of the L3 phase –range of measure: 45÷65Hz 
precision: ±0,5% ±1 digit 

powers 

phase and three phase system reactive and active power 
range of measure: 0,001÷9990kW - 0,001÷9990kVAr - 0,001÷9990kVA 
precision: ±1% ±1 digit  -  management average and maximum value 

power factor 

phase and three phase power factor 
range of measure: -0,1÷0,1 / precision: ±1% ±1 digit - management average and maximum value 

energy measure 

three phase system active, reactive and apparent energy 
range of measure:  0÷99999999,9 kWh / kVArh 

class 2 ( IEC 1036) 

precision: ±1% 

hours counter 

precision: ±1%; resolution 1/10 of hour 

AUXILIARY POWER SUPPLY, INPUTS 
auxiliary power 
supply 

standard 380-415V ±15%  -  optional 100-125 / 220-240V ±15% 
frequency 45-65Hz - consumption 3VA 
voltage from the voltage measure input 

voltage inputs 

from 20 to 500V phase-phase (dependent from auxiliary power supply); permanent ov20% -  input 
impedance: 1 M

 

insertion on three phase line with 3 wires, 4 wires and single phase 
insertion in MT with external TV and transforming rate programmable from 0.1 to 400.0 

current inputs 

from 0,02 to 5A; permanent overload 30% - from external TA with secondary 5A, 
primary programmable from 5 to 10000A  -  auto-consumption <0,5VA 

 INPUTS / OUTPUTS 
digital outputs 

Two outputs with common, optomos 12÷230Vac/dc, max 150mA,  
Insulation: 3kV for 60 second 
Pulse Function: 
Weight programmable 0,01-0,1-1-10 kWh/pulse 
Pulse duration 100-200-300 400 500 milliseconds selectable 
DO1: active energy pulse output 
DO2: reactive energy pulse output 

serial output 

One optional output RS485, baud rate selectable, MODBUS-RTU protocol 
Insulation: 3kV for 60 second 

GENERALS 
display, operators  4 displays with red LED 10mm everyone of 3 digit by 7 segments 

3 push-button for selecting measure and programming 

mechanic 

protection degree: IP52 frontal  -  IP20 enclosure and terminals  -  weight: about 0,5 kg 
connections with screw terminals for cable 2,5 mm

2

 

enclosure thermoplastic self-extinguishing 
EMM-R4h: flush mounting DIN 96x96mm, depth 56mm 
EMM-µ4h: flush mounting DIN 72x72mm, depth 95mm 

environmental working 

temperature: -10÷60°C;  humidity <90% 

storing temperature: -25÷70°C 
insulation test: 3 kV for 1 minute 

standards 

CEI EN 50081-2; CEI EN 50082-1; 
CEI EN 61010-1 

 
 
 
 

NOTE  

At reason of the evolution of standards and products, the company reserves to modify in every time  the features of the product described in this 
document, that it’s necessary to verify preventively. 
The liability of the producer for damage caused by defect of the product ”can be reduced or deleted (…) when the damage is caused joint by a defect of 
product or for blame of the damaged or a person of which the damaged is responsible” (Article 8, 85/374/CEE).

 

Summary of Contents for EMM-M4H

Page 1: ...c OPTIONS internal CT digital output in alternative to the serial port serial port in alternative to the digital output power supply different from standard version current input 1A MEASURED PARAMETERS parameters unit of measurement initial identification phase and three phase voltages V kV V L1 N V L2 N V L3 N V L N phase to phase and three phase system voltages V kV V L1 L2 V L2 L3 V L3 L1 V L L...

Page 2: ...tage range of measurable voltage L2 L3 phase to phase power supply 400V 300 500V phase to phase 175 290V phase neutral 230V 175 290V phase to phase 130 170V phase neutral 110V 85 145V phase to phase 50 85V phase neutral L3 N phase neutral power supply 230V 300 500V phase to phase 175 290V phase neutral 110V 175 290V phase to phase 100 170V phase neutral The standard version allows to apply the ins...

Page 3: ...TION ON THREE PHASE LINE WITH 4 WIRES AND 3 VT EMM P1 S1 P1 P1 P2 S1 S1 S2 INSERTION ON THREE PHASE LINE WITH 3 OR 4 WIRES on line with 3 wires without neutral or with neutral not supplied the N terminal must not be conneccted LOAD EMM P1 S1 P1 P1 P2 S1 S1 S2 N L1 L2 L3 N L1 L2 L3 ...

Page 4: ... P2 S1 S2 N L1 L2 L3 AMPEROMETRIC INSERTION ON THREE PHASE LINE WITH 2CT AARON insertion VOLTAGE INSERTION ON THREE PHASE LINE WITH 3 WIRES AND 2 VT This voltage insertion is possible only with the version with internal CT t suffix LOAD EMM L1 L2 L3 S2 S2 S1 S1 P2 P2 P1 P1 ...

Page 5: ...INSERTION ON BALANCED THREE PHASE LINE WITH 3 OR 4 WIRES on line with 3 wires without neutral or with neutral not supplied the N terminal must not be connected L1 L2 L3 LOAD EMM P1 P2 S1 S2 INSERTION ON SINGLE PHASE Only for models with power supply phase neutral Vaux L3 N N L ...

Page 6: ...D E energy counters excluded The voltage values are referred to the three phase system The k LED displays the reading in kilo x1000 Using the C key the display indicates the type of the energy displayed Using the A and B keys the display indicates the type of average or maximum value A C when pressing simultaneously the instrument pass to the following menu instrument programming SETUP energy coun...

Page 7: ...0 kW kVAr pulse version with digital output 01 0 kW kVAr pulse 0 10 kW kVAr pulse 0 01 kW kVAr pulse seT TPL Increase from 100 to 500 mS in step by 100 mS Decrease version with digital output seT ID ADR Increase Set address of network from 001 to 127 Decrease version with serial output seT SER BDR Set baud rate 19200 baud 19 2 serial interface 9600 baud 9 60 version with serial output 4800 baud 4 ...

Page 8: ... energy visualization type after the visualization of the temperature With TOT PAR will have the visualization of the partial and total energy counters With NORMAL there will be only the visualization of total counters that it s possible to reset from RESET menu Programming insertion mode 3PH In a unbalance three phase system it s necessary to set UN_BAL unbalance while in a balance system only on...

Page 9: ...um values and all energy hours counters Entry to menu seT UP seT Up RESET SET DO1 SET DO2 SET HR_ OFF OFF the visualization depends on the settings and the I O status RESET PEA NO YES Confirm Reset Deleting maximum values max RESET AVG NO YES Confirm Reset Deleting average values avg and maximum demand maxD RESET EN NO YES Confirm Reset Deleting energy counters RESET ALL NO YES Confirm Reset Delet...

Page 10: ...ress A key to confirm CHOOSE THE PARAMETER TO LINK TO THE DIGITAL OUTPUT With an alarm modality set it s necessary to select the parameters associated to the alarm output by pressing the B and C keys until the parameter choice appears on the third part L3 of F display and the glowing the corresponding led on the D bar Press A key to confirm the set SET THE HIGH AND THE LOW THRESHOLDS On F display ...

Page 11: ...eresis value With only the LO threshold set the alarm condition is activated when the parameter set in alarm drop below the threshold The digital output is enabled only if the alarm condition remain activated for all delay time set From the activation of the digital output the restore is automatic when the parameter grow above the hysteresis value With both LO and HI threshold set the alarm condit...

Page 12: ...ore time the B key to select the parameter and the A key to confirm it SET THE THRESHOLD Subsequently it s necessary to set the threshold using the B to increase and C to decrease keys Confirm with A key I O INFO PAGE After the hour counter set the I O info page appears in F displays on the second part L2 the status of the first digital output DO1 on the third part L3 the status of the second digi...

Page 13: ...same way of the section 1 press the C button to select the parameter that can be displayed and indicated from E LED The voltage values are of the three phase system the frequency is of the L3 channel Visualization energy and hours counters With the C key it s possible to visualize on F display the active reactive and apparent energy counters One segment of the right digit of the G display in corre...

Page 14: ...hase currents I L1 max avg I L2 max avg I L3 max avg max maxD avg maximum of average phase currents max demand three phase power W max avg VAr max avg VA max avg max maxD avg maximum of average three phase powers maximum demand phase currents I L1 avg I L2 avg I L3 avg max maxD avg average phase currents three phase power W avg Var avg VA avg max maxD avg average three phase powers NOTE relative t...

Page 15: ...verter and the end of the network last instrument connected Use always twisted cables with minimum section of 0 36mm2 22AWG and lower capacity of 60 pF m i e BELDEN cable type EIA RS485 Ref 3105A Shielded connection Should it be the case of long distance networks ambiences where there have been placed energy transporting cables or ambiences subject to be electrically disturbed it is suggested to u...

Page 16: ...ires 4 wires and single phase insertion in MT with external TV and transforming rate programmable from 0 1 to 400 0 current inputs from 0 02 to 5A permanent overload 30 from external TA with secondary 5A primary programmable from 5 to 10000A auto consumption 0 5VA INPUTS OUTPUTS digital outputs Two outputs with common optomos 12 230Vac dc max 150mA Insulation 3kV for 60 second Pulse Function Weigh...

Reviews: