Instrument Calibration
515 HC04 - 8 June 2007
47
General Setup Parameters
↓
→
UNITS PARAMS INPUTS OUTPUTS ALARMS COMMS TM/LOG
SETUP
TEST END
DEFAULT TOTAL
The instrument displays the default Total when the user presses the
key.
If the display timeout is enabled, the instrument displays the default Total
when there is no user action for the period of the display timeout period.
Press
or
to select the default total display.
SUPPLY
VOLT
The instrument provides a power-limited supply for external transducers.
Press
or
to set the transducer supply voltage between 8 and 24
volts DC as required.
T-OUT
MODE
If the Display Timeout mode is enabled, and there is no user activity for
the defined timeout period, the display panel returns to the default
display.
This function is useful for the following reasons:
•
to return the display to a preferred variable after the user has finished
reading other information,
•
to cancel the calibration mode and return to the default display if the
user does not exit from the calibration mode for any reason.
Press
or
to select the display timeout function as follows:
•
DISABLE
- Timeout is completely disabled.
•
EN DISP
- Timeout is enabled during Normal mode and Calibration
View mode.
•
EN EDIT
- Timeout is enabled during Calibration Set mode.
•
EN ALL
- Timeout is enabled for all modes.
T-OUT
SEC
The Display Timeout period defines the delay for the Display Timeout
mode if it is enabled.
The display timeout period can be from 10 to 99 seconds.
RESET
MODE
The Totals Reset mode can be configured to reset the non-accumulated
totals to zero.
Press
or
to select the reset mode as follows:
•
NONE -
The user cannot reset the non-accumulated totals.
•
INSTANT
- When the user presses the
key, the instrument
resets all non-accumulated totals.
•
DELAYED -
When the user presses the
key
and holds it for
two seconds, the instrument resets all non-accumulated totals.
SET
TOTAL
RESET
RESET
Summary of Contents for 515
Page 4: ...iv 515 HC04 8 June 2007 ...
Page 8: ...viii 515 HC04 8 June 2007 ...
Page 16: ...Introduction 8 515 HC04 8 June 2007 ...
Page 60: ...Instrument Calibration 52 515 HC04 8 June 2007 ...
Page 80: ...Communications 72 515 HC04 8 June 2007 ...
Page 82: ...74 515 HC04 8 June 2007 ...
Page 88: ...80 515 HC04 8 June 2007 ...