![Contrec 515 Operation Manual Download Page 15](http://html.mh-extra.com/html/contrec/515/515_operation-manual_2658179015.webp)
Introduction
515 HC04 - 8 June 2007
7
Some applicable ranges of lines sizes and beta values are as follows:
Approvals
This instrument conforms to the EMC-Directive of the Council of European
Communities 89/336/EEC and the following standards:
•
Generic Emission Standard EN 50081-1 Residential, Commercial &
Light Industry Environment.
•
Generic Emission Standard EN 50081-2 Industrial Environment.
•
Generic Immunity Standard EN 50082-1 Residential, Commercial &
Light Industry Environment.
•
Generic Immunity Standard EN 50082-2 Industrial Environment.
In order to comply with these standards, the wiring instructions in
Type of Cone
Line sizes(mm)
(in)
β
McCrometer
Precision tube V-Cone
12
≤
D
≤
1830
0.5
≤
D
≤
72
0.45
≤ β ≤
0.80
McCrometer
Wafer-Cone
12
≤
D
≤
152
0.5
≤
D
≤
6
0.45
≤ β ≤
0.80