MAINTENANCE
Superterm CIC1800 / CICP1400UL
87
Backup Battery Replacement
WARNING
Verify that the AC source voltage is switched off
at the breaker panel before proceeding with
backup battery replacement.
1)
Open the Superterm cabinet and locate the
backup battery secured to the lower center
ledge of the cabinet (see Figure 57).
2)
Remove the two #6-32 x 1/4" screws securing
the backup battery to the Superterm cabinet.
3)
Disconnect the RED lead from pin 6 (labeled
+BAT) of the power input terminal strip (refer
to page 12, Step-Down Transformer
Connection for specific information).
4)
Disconnect the BLACK lead from pin 5
(labeled -BAT) of the power input terminal
strip.
5)
Disconnect the RED lead from the POSITIVE
terminal of the battery.
6)
Disconnect the BLACK lead from the
NEGATIVE terminal of the battery.
7)
Remove the old battery.
8)
Install the new battery in the reverse order of
the removal.
Backup Battery In-Line Fuse Replacement
WARNING
Verify that the AC source voltage is switched off
at the breaker panel before proceeding with in-
line fuse replacement.
1)
Open the Superterm cabinet and locate the
backup battery secured to the lower center
ledge of the Superterm cabinet (see Figure 57).
2)
Remove the old fuse from the fuse holder and
replace with a new 3AG, 3A fuse.
3)
Close the Superterm cabinet and restore the AC
source voltage.
Figure 57 - Superterm Battery/In-Line Fuse
Location
Summary of Contents for SUPERTERM CIC1800
Page 27: ...Figure 15 Superterm Circuit Board Relay Location...
Page 53: ...Figure 34 COM1 Terminal Strip Connection...
Page 55: ...Figure 35 Connecting Auxiliary RS 232 and RS 485 Devices to the Superterm...
Page 57: ...Figure 36 Expansion Input Output Board Layout in Superterm Cabinet...
Page 63: ...Figure 41 DI DO Board Layout Figure 42 DI DO Board to Superterm Power Connection...
Page 65: ...Figure 43 DI DO Board Alarm Input Terminal Strip...
Page 67: ...Figure 45 DI DO Board Relay Output Connections and Address Setting...
Page 75: ...Figure 47 COM1 COM2 and MONITOR Jumper Locations and Settings...
Page 77: ...Figure 48 Jumper Locations and Settings...
Page 79: ...SETTINGS Superterm CIC1800 CICP1400UL 79 Figure 49 Superterm Door Strike Jumper Settings...
Page 83: ...Figure 53 256K Memory Upgrade Installation...
Page 85: ...UPGRADING Superterm CIC1800 CICP1400UL 85 Figure 55 2MB Expansion Board Installation...