COMMUNICATION CONNECTION
Superterm CIC1800 / CICP1400UL
50
RS-422 to RS-422 MULTIDROP Network
Figure 33 shows the required connections for an
RS-422-toRS-422 MULTIDROP network.
Table 33 lists the necessary connections between:
A host computer and the first Superterm in the
network,
and
The first Superterm in the network and the
following Superterms (32 maximum) in a
network.
RS-422 to RS-422 MULTIDROP Drain
Wires
Ground the drain wires for all RS-422 cables in the
network to the Superterm ground posts.
NOTE:
Connect all drain wires together starting
at the LAST Superterm in the network and working
toward the FIRST Superterm in the network.
Connect the drain wire from the FIRST Superterm
in the network to the drain wire at the Polling Line
Converter (see Figure 33).
Connect the drain wire from the Polling Line
Converter to the ground at the rear of the host
computer.
RS-422 to RS-422 MULTIDROP Jumper
Setting
Operating a Superterm network in the
MULTIDROP mode requires setting the MODE 1
and EOL2 jumpers.
Refer to page 70 for information regarding setting
the MODE I jumper.
Refer to page 66 for information regarding setting
the EOL2 jumper.
Table 33 - RS-422 to RS-422 MULTIDROP Network Connections
Host Computer
Superterm #1
Superterm #2
Superterm 3#
Superterm #4
Last Superterm
MODE1 jumper= MD MODE1 jumper= MD MODE1 jumper= MD MODE1 jumper= MD MODE1 jumper= MD
EOL2 jumper = OUT EOL2 jumper = OUT EOL2 jumper = OUT EOL2 jumper = OUT
EOL2 jumper = IN
Signal Connector/Pin
Connector/Pin
Connector/Pin Connector/Pin Connector/Pin
RS-422 TXD+
POLL 13 (MD/R+)
POLL 13 (MD/R+)
POLL 13 (MD/R+)
POLL 13 (MD/R+)
>> POLL 13 (MD/R+)
RS-422 TXD-
POLL 14 (MD/R-)
POLL 14 (MD/R-)
POLL 14 (MD/R-)
POLL 14 (MD/R-)
>> POLL 14 (MD/R-)
RS-422 RXD+
POLL 11 (MD/T+)
POLL 11 (MD/T+)
POLL 11 (MD/T+
POLL 11 (MD/T+)
>> POLL 11 (MD/T+)
RS-422 RXD-
POLL 12 (MD/T-)
POLL 12 (MD/T-)
POLL 12 (MD/T-)
POLL 12 (MD/T-)
>> POLL 12 (MDT-)
Summary of Contents for SUPERTERM CIC1800
Page 27: ...Figure 15 Superterm Circuit Board Relay Location...
Page 53: ...Figure 34 COM1 Terminal Strip Connection...
Page 55: ...Figure 35 Connecting Auxiliary RS 232 and RS 485 Devices to the Superterm...
Page 57: ...Figure 36 Expansion Input Output Board Layout in Superterm Cabinet...
Page 63: ...Figure 41 DI DO Board Layout Figure 42 DI DO Board to Superterm Power Connection...
Page 65: ...Figure 43 DI DO Board Alarm Input Terminal Strip...
Page 67: ...Figure 45 DI DO Board Relay Output Connections and Address Setting...
Page 75: ...Figure 47 COM1 COM2 and MONITOR Jumper Locations and Settings...
Page 77: ...Figure 48 Jumper Locations and Settings...
Page 79: ...SETTINGS Superterm CIC1800 CICP1400UL 79 Figure 49 Superterm Door Strike Jumper Settings...
Page 83: ...Figure 53 256K Memory Upgrade Installation...
Page 85: ...UPGRADING Superterm CIC1800 CICP1400UL 85 Figure 55 2MB Expansion Board Installation...