BUILT-IN HOB
GAS CONVERSION
Burners in your hob can be operated by different gases by installing injectors suited for gases required
to be fired. Contact with the authorized service for your gas type changes.
Injectors change should be carried out by the authorized service staff as follows;
• Remove fire bars and burners by lifting them upward.
• Remove injectors by turning counter-clockwise and reassemble new injectors suited for gas types to
be used.
(See Table 1)
• Tighten injectors properly.
IMPORTANT:
Tightening the injector too much causes to become worn and occur gas leakage, for this
treason do not force too much when you make sure of tightening the injector adequately.
• After installing the injectors, check the gas leakage by foam. For this process, foam the bottom of
injectors, push over the injector with your finger so as to close the gas outlet and check whether
bubbles occur in the connection point of injector or not
.
• In order to adjust injectors to minimum, turn the screw located on valve with a screwdriver to
minimum position.
• After the authorized staff completes the settings, he should readjust seal rings and markings all over
the appliance and replace the labels including information relating to the used gas with the labels
including information relating to the new adjusted gas.
• After completing injector replacement, place the fire bars and burners and make sure of fitting them
properly.
WARNING:
The gas conversion must be performed by qualified service personnel.
Summary of Contents for CAG-113
Page 1: ...ANKASTRE OCAK KULLANMA KILAVUZU...
Page 15: ...ANKASTRE OCAK S zd rmazl k contas ba lant ekli...
Page 40: ...BUILT IN HOB Connection type for 20 30 40 mm bench Point A Connection holes...
Page 41: ...BUILT IN HOB Connection type of sealing ring...
Page 51: ...BUILT IN HOB...
Page 63: ...ANKASTRE OCAK...
Page 64: ......