4. Using the I/O Address Map
36
ADI16-4(FIT)GY
List of Commands
Following is a list of ADI16-4(FIT)GY commands that are issued to "Output port +24":
Table 4.7. List of commands
No.
HEX
Function
Data length
00
0
Initialization
0-bit
01
1
Interrupt source mask
8-bit
02
2
Sampling settings
8-bit
03
3
Input range
8-bit
04
4
Internal sampling clock
32-bit
05
5
Timer start
0-bit
06
6
Timer stop
0-bit
07
7
FIFO memory flag
8-bit
08
8
Number of data items stored in
FIFO
8-bit
09
9
FIFO memory clear
0-bit
10
A
Calibration Data Setting
16-bit
11
B
EEPROM Data Setting
16-bit