54
5.9
INSTALLATION OF THE DOSING TUBE
/
Push the compression nut approximately 2 cm over the dosing tube(see fig. 8).
/
If necessary, shorten the dosing tube.
/
Insert the dosing tube up to the stop in the connector of the injection nozzle.
/
Push the compression nut onto the connector, screw in place and tighten with an 8mm open-
ended spanner.
/
Check for correct seating by pulling.
Disconnecting the dosing tube:
/
Undo the compression nut with an open-ended spanner and screw off.
Refitting of the dosing tube:
/
Cut off the dosing tube shortly after the indentation. The indentation results from the tightening of the
compression nut. Fit the dosing tube.
Select the tightening torque (about 4 Nm) so that the compression nut clamps the
dosing tube and seals it.
Limiting of the tightening torque:
Tighten using the open-ended spanner until it slides on the hexagon faces of the
compression nut.
Fig. 8: Injection nozzle
Dosing tube
Compression nut
Connector
Injection nozzle
Injection nozzle hose