"Right" take-off:
Fig. 27 Changing springs, series connection with right take-off
BEF185 – BEF500
→
On the flange side, loosen the hex screws [5] of the connection between the end flange and the reel body.
→
Remove the silicone joint between the end flange and the reel body, then carefully pull off the end flange with its bearing
flange [6].
→
Loosen the threaded pin of the spacer [7] and pull it off the axis.
→
Loosen the threaded pin of the fixed spring nut [8] and take it out.
→
Lift the protective housing(s) [9] out with the spring nut.
→
Loosen the hex nuts [10] of the fixed protective housing [11] on the outside of the end flange on the slip ring body side.
→
Carefully lift out the protective housing [11].
BEF150
→
On the flange side, loosen the cylinder screws [5] of the connection between the end flange and the reel body.
→
Remove the silicone joint between the end flange [6] and the reel body [13], then carefully pull off the end flange with its
bearing flange.
→
Loosen the threaded pin [11] of the slip ring body and carefully pull the axis out until the threaded pins [9] of the spring nut [12]
are accessible.
→
Loosen the threaded pins of the spacer [10] and the spring nut, and take them out.
→
Carefully lift out the protective housing [7, 8].
CAUTION!
The towing part protective housing [8] is suspended in the guide groove of the reel body
and is held in place by a plastic profile.
→
Take out the plastic profile and then the protective housing [8].
BEF185 – BEF500
BEF150