7.2.1
Connecting the feed cable
WARNING!
Danger of death by electrocution!
Contact with components carrying electrical power can lead to death or severe injury by
electrocution. Danger of injury due to shock reactions, falling, or being thrown away due to
electrical shock.
→
Before starting electrical connection work, disconnect all relevant cables from power and
secure the device or system against being turned back on
→
Follow the five safety rules!
→
Earth the device on the earthing connection (PE) of the slip ring body
→
Unscrew and remove the cap of the slip ring body.
→
Guide the feed cable and earthing cable through the cable entry (masonry, beams, etc.), the reel flange and the reel axis to
the slip ring body.
CAUTION!
Terminal diagram
→
Follow the attached terminal diagram for connection work.
→
Connect the cables.
→
Check all connections for secure, firm seating.
→
Replace the slip ring body cap and screw it back into place.
→
Wind the reel cable by hand without twisting and tie the cable end down.
The connections to the slip ring variants are shown in the illustrations below:
Slip ring
Connection material to be used
Type 45
None needed, since the only terminal board variant possible has mantle terminals
Type 13
M6 cable shoe
Type 15
M8 cable shoe
Type 16
M8 cable shoe
Type 18
None for terminal board variants with mantle terminals; M5 cable shoe for direct wiring
Type 19
M8 cable shoe