"Left" take-off:
Fig. 26 Changing springs, series connection with left take-off
BEF185 – BEF500
→
On the flange side, loosen the hex nuts [10] of the protective housing bolts and the hex nuts [5] of the connection between the
end flange and the reel body.
→
Remove the silicone joint between the end flange and the reel body, then carefully pull off the end flange with its bearing
flange [6].
→
Loosen the threaded pin of the spacer [7] and pull it off the axis.
→
Carefully lift out the protective housing [9, 11].
BEF150
→
On the flange side, loosen the cylinder screws [5] of the connection between the end flange and the reel body.
→
Remove the silicone joint between the end flange [6] and the reel body [0], then carefully pull off the end flange with its
bearing flange.
→
Loosen the threaded pin of the spacer [10] and pull it off the axis.
→
Carefully lift out the protective housing [7, 8].
CAUTION!
The towing part protective housing is suspended in the guide groove of the reel body and
the first spring [7] on the flange side.
BEF185 – BEF500
BEF150