Operating Instructions
750 W 27 V pickup
CQF 04/2 + Interface M12
BAL9100-0145a-EN
www.conductix.com
translated document
Page 38 of 40
14
Accessories
14.1
Power output
The output cable, which leaves the device, can be ordered from Conductix-Wampfler on
request. Generally, however, the requirements with respect to the choice of the cable
cross-section described in chapter 4.5.1 apply.
Connecting cable 2.5 m one-sided with plug: 91212-339-3124279
Details about this connecting cable can be found in the table below. The materials required to connect the power output using a plug
are listed. Please refer to chapter 15 for the tools required for assembly. On-site conditions may require additional material.
Description
Required
quantity
Material number
ILME
Material number
Harting
Sleeve housing (plastic)
1
CQ 08VK
19 12 008 0429
Screw connection
(plastic)
1
CRQ 16
19 12 005 5157
Male insert
1
CQM 04/2
09 12 006 3041
Crimp contact pins male
4 mm² / AWG12
5
CXMA 4.0
09 32 000 6107
Crimp contact pins
male 1.5 mm²
2
CDMA 1.5
09 15 000 6101