8.3
Position tolerances
The available power of a device depends on the strength of the primary field; i.e. the position in which the device stands above the
IPT
®
track is important. The power specifications are based on a nominal air gap of 10 mm (floor surface to the lower edge of the
device) and positioning above the primary track horizontally in the middle. The following graphs show the typically available output
powers over a straight IPT
®
track as functions of a 1. vertical offset (horizontal offset constant at 0 mm) and 2. horizontal offset
(vertical offset at 10 mm). The non-variable parameter should be understood as compliant with the nominal position. The output
power is also influenced by the layout of the IPT
®
tracks, e.g. branches, curves, ferromagnetic materials in the environment, etc.
Further information can be found in the chapter 7.5.