Operating Instructions
750 W 27 V pickup
CQF 04/2 + Interface M12
BAL9100-0145a-EN
www.conductix.com
translated document
Page 23 of 40
7.5
Installation location and conditions
WARNING!
Risk of injury from improper installation!
Improper installation can result in serious injury to person and property.
→
Install the device in an environment and under conditions as specified in this document only.
→
Mount the unit in a horizontal position with the heat sink facing upwards on a solid support
structure/surface.
→
Make sure there is enough space around the unit to both limit the influence of ferromagnetic material
and provide adequate ventilation for cooling.
NOTE!
The available output power as specified in this document strongly depends on the ambient conditions of
the device. Follow the instructions in this document.
7.5.1
Position
A horizontal position maximizes the efficiency of convection cooling. With inclined mounting, the possible output power must be
reduced. Mounting with the heat sink pointing downwards is not permitted.
The devices must be mounted parallel to the primary track and centered over the lines (see drawing). A nominal distance of 10 mm
between the underside of the device and the ground surface must be ensured. Correct installation of the primary track, according to
the installation instructions, is required to ensure the specified output power in this case.
7.5.2
Required air flow
The thermal loss of the pickup is dissipated by convection and radiated cooling only. Make sure that the air is free to flow around the
device or through the cooling fins at any time at min. 0.1m/s. It is also important to protect the device from additional heating, e.g. by
sunlight, by the warm exhaust of other devices such as frequency converters or braking resistors, etc.
WARNING!
Risk of injury from improper mounting!
If the device is mounted improperly, the performance of the device will be restricted. Damage can
occur and the service life may be reduced.
→
Design enclosed installation situations so that adequate ventilation is provided and that the heat
released by the unit, up to 50 W under full load, will not cause any damage.