Operating Instructions
750 W 27 V pickup
CQF 04/2 + Interface M12
BAL9100-0145a-EN
www.conductix.com
translated document
Page 15 of 40
4.5.1
DC power output connection
(Shown: socket side at the pickup)
Source: Harting
PIN 1
+ 27 V DC
PIN 2
+ 27 V DC
PIN 3
0 V
PIN 4
0 V
Ground
PIN11 pilot contact 1
PIN12 pilot contact 2
NOTE!
Make sure that all output lines are dimensioned according to the maximum output current. The output
leads must have sufficiently large cross-sections to keep the voltage drops on the leads as small as
possible.
The device is connected to the load using all four outputs, two positive and two negative. The cable lengths of the connecting cables
of the same polarity must be within 2% of their total length so that the current is divided equally.
4.5.2
Interface connection
(shown: socket side)
PIN 1
24 V DC isolated
PIN 2
0 V DC isolated
(150 mA max. No external supply: see section 8.1)
PIN 3
COM
(Together for the 3 output relays “Warning,” “Error” and “Status”)
PIN 4
Release
(Must be connected for starting up the pickup! See section 8.1)
PIN 5
Warning
PIN 6
Error
PIN 7
Status
(Relay with potential-free contacts, for 30 V DC/5 A max.)
PIN 8
Ground